AS302P Single Phase Smart Meter
____________________________________________________________________
Tariff Block Counter Matrix
Tariff TOU Register Matrix
Tariff TOU Block Register Matrix
Time Debt Registers [1 ... 2]
Constant Data
SMETS2 reference
AS302P Identifier
Manufacturer Identifier
Model Type
Meter Variant
Randomised Offset Number
Internal Data
SMETS2 reference
Installation Credentials
Configuration Data
SMETS2 reference
Alerts Configuration settings
Auxiliary Load Control Switch Calendar
Auxiliary Load Control Switch Description
Average RMS Over Voltage
Average RMS Under Voltage Threshold
Average RMS Voltage Measurement
Period
Billing Calendar
Contact Details
Currency Units
Customer Identification Number
Debt Recovery per Payment
Debt Recovery Rates [1 ... 2]
Debt Recovery Rate Cap
Device Log
Disablement Threshold
Emergency Credit Limit
Emergency Credit Threshold
Meter Security Credentials
Load Limit Period
Load Limit Power Threshold
Load Limit Restoration Period
Configuration Data (Contd)
Load Limit Supply State
© Honeywell - M450 001 1D - 23.05.2019
Matrix for storing Block Counters for Block Pricing
Matrix for storing Tariff Registers for Time-of-use Pricing.
Matrix for storing Tariff Registers for Time-of-use with Block Pricing.
Two registers recording independent debts to be recovered over time when
operating Time-based Debt Recovery in Prepayment Mode.
Description
A globally unique identifier used to identify an individual AS302P based on the
EUI-64 Institute of Electrical and Electronic Engineers standard.
An identifier used to identify the manufacturer of the meter
An Identifier used to identify the model of the meter
An Identifier used to identify if the meter is Single, Twin element or Polyphase
Randomly Generated 0 or 1
Describes Data that Remains Constant and is not Available Outside the
Meter
Credentials Unique to the Meter
Description
Generate/Send an Alert
Set of Switching Rules for up to 5 Auxiliary Load Control switches
Description of Control of Each Auxiliary Load Control Switch
The average RMS voltage above which an over voltage condition is reported
The average RMS voltage below which an under voltage condition is reported.
The length of time in seconds over which the RMS voltage is averaged.
A calendar defining billing dates for the storage of billing related information
The name and contact telephone number of the Supplier.
The Currency Units currently used by the meter (Pound/Euros)
A number issued to meter for display on the User Interface.
The percentage of a payment to be recovered against debt
Two debt recovery rates in Currency Units per unit time
The maximum amount in Currency Units per unit time that can be recovered
The Security Credentials for each of the Type 1 Devices and Type 2 Devices
The threshold in Currency Units for controlling when to Disable the Supply
The amount of Emergency Credit in Currency Units to be made available to a
Consumer
The threshold in Currency Units below which Emergency Credit Balance may be
activated
The Security Credentials for Meter
Length of time in which Active Power Import continuously exceeds the Load Limit
Power threshold before Load Limit Event Occurs
The Active Power threshold in kW above which the measurement of a Load Limit
Period is commenced.
The length of time in seconds after the Supply has been Armed following a Load
Limiting Event before the Supply is Enabled by AS302P.
Control the state of the Supply in the case of a load limiting occurring, being
Disabled or unchanged.