• Go over "Installation Guidelines" on page 107 to ensure that you work safely.
• Turn off the server and peripheral devices and disconnect the power cords and all external cables (see
"Power off the server" on page 12).
• If the server is installed in a rack, slide the server out on its rack slide rails to gain access to the top cover,
or remove the server from the rack.
Watch the procedure. A video of this procedure is available from the following links:
https://www.youtube.com/playlist?list=PLYV5R7hVcs-C6QgmsUMRG6ul0bHzrGmsG
https://list.youku.com/albumlist/show/id_54461099
Procedure
Step 1.
Make preparations for this task.
a.
Remove the top cover (see "Remove the top cover" on page 214).
b.
Remove the fan cage assembly (see "Remove the fan cage assembly" on page 130).
c.
Remove the system board air baffle (see "Remove the system board air baffle" on page 200) or
the processor and memory expansion tray and the expansion tray air baffle (see "Remove the
processor and memory expansion tray" on page 190).
a.
Gently pull and disengage every installed power supply unit.
Step 2.
Disconnect the power backplane cable and remove if from the cable clip.
Figure 82. Disconnecting the power backplane cable
Step 3.
Grasp and lift the power backplane to remove it.