DCR-IP5/IP5E/IP7BT/IP7E
1-2-3.

INITIALIZATION OF B PAGE DATA

(DCR-IP7BT/IP7E)

Switch setting:
POWER ................................................................. MEMORY
Memory Stick slot ............................... Insert a Memory Stick

1. Initializing the B Page Data

Note: If the B page data has been initialized, the following
adjustments need to be performed again.

1) Modification of B page data

2) Writing the network default setting value

Adjusting page
Adjusting Address
Initializing Method:
Order Page Address Data
1
0
01
2
5
0E
3
5
01
4
5
00
5
6
5
0E
7
2. Modification of B Page Data
If the B page data has been initialized, change the data of the "Fixed
data-2" address shown in the following tables by manual input.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the camcorder may
not operate.
3) When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
Processing after Completing Modification of B Page data
Order Page Address Data
1
2
00
2
2
01
B
00 to FF
Procedure
01
Set the data.
00
Set the data, and press PAUSE
button.
F3
Set the data, and press PAUSE
button.
01
Set the data, and press PAUSE
button.
Wait for 3 sec.
Check that the data changes to
"01".
Perform "Modification of B Page
Data".
Procedure
29
Set the data
29
Set the data, and press PAUSE
button.
3. Writing the Network Default Setting Value
Writing method:
Order Page Address Data
1
0
01
2
5
01
3
5
09
4
5
0A
5
5
00
6
5
0E
7
0
01
4. B Page Table
Note: Fixed data-1: Initialized data. (Refer to "1. Initializing the B Page
Data".)
Fixed data-2: Modified data. (Refer to "2. Modification of B Page
Data".)
Address
00 to 0F
Fixed data-1
10
Fixed data-2
11 to FF
Fixed data-1
5-14
Procedure
01
Set the data.
E7
Set the data, and press PAUSE
button.
80
Set the data, and press PAUSE
button.
Set the following data, and press
PAUSE button.
03: US model
01: Except US model
01
Set the data, and press PAUSE
button.
Check that the data is "01".
00
Set the data.
Remark