1-2-2.
INITIALIZATION OF C, 4, 8, 9 PAGE DATA
1. Initializing the C, 4, 8, 9 Page Data
Note1: If "Initializing the C, 4, 8, 9 Page Data" is performed, all
data of the E page, F page and 7 page will be initialized.
(It is impossible to initialize a single page.)
Note2: If the C, 4, 8, 9 page data has been initialized, following adjustments
need to be performed again.
1) Modification of C, 4, 8, 9 page data
2) Serial No. input
3) Servo and RF system adjustments
4) Video system adjustments
5) Color view finder system adjustments
6) LCD system adjustments
Adjusting page
C
Adjusting Address
10 to FF
Adjusting page
4
Adjusting Address
00 to FF
Adjusting page
8
Adjusting Address
00 to FF
Adjusting page
9
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
1
0
01
01
2
3
81
00
3
3
80
0F
4
3
80
5
2. Modification of C, 4, 8, 9 Page Data
If the C, 4, 8, 9 page data has been initialized, change the data of the
"Fixed data-2" address shown in the following table by manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the camcorder may
not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of C, 4, 8, 9 Page data
Order Page Address Data
1
2
00
29
2
2
01
29
Procedure
Set the data.
Set the data, and press PAUSE
button.
Set the data, and press PAUSE
button.
Check that the data changes to
"1F".
Perform "Modification of C, 4, 8,
9 Page Data".
Procedure
Set the data
Set the data, and press the PAUSE
button.
3. C Page Table
Note1: Fixed data-1: Initialized data. (Refer to "1. Initializing the C, 4, 8,
9 Page Data".)
Fixed data-2: Modified data. (Refer to "2. Modification of C, 4, 8,
9 Page Data".)
Address
Initial value
00 to 0F
10
00
11
00
12
00
13
00
14 to 19
1A
80
1B
80
1C
70
1D to 1E
1F
00
20
00
21
00
22
00
23
00
24
00
25
00
26
00
27
00
28
00
29
00
2A
00
2B
00
2C
80
2D
2E
80
2F
30
19
31
9A
32
19
33
9A
34
00
35
00
36
00
37
00
38 to 3B
3C
07
3D
00
3E
00
3F
00
40
00
41
00
42
00
43
00
44
00
45
00
46
00
47
00
48
00
49
00
4A
00
5-11
DCR-IP5/IP5E/IP7BT/IP7E
Remark
CAP FG duty adj.
Fixed data-1
CAP FG duty adj.
Fixed data-1
CAP FG duty adj.
Emergency memory address
T reel FG duty adj.
Fixed data-1
CAP FG duty adj.
Fixed data-1
Switching position adj.
XREC ACT adj.
Fixed data-1
Chroma BPF fo adj.
Pch LMS adj.