1-2. INITIALIZATION OF D, E, F PAGE DATA

1. Initializing the D,E,F Page Data
Note: If the D,E,F page data has been initialized, "Modification of D, E, F
Page Data" and all adjustments need to be performed again.
Adjusting Page
D
Adjusting Address
00 to 6F
Adjusting Page
F
Adjusting Address
00 to FF
Adjusting Page
E
Adjusting Address
00 to FF
Initializing Method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 6, address: 00, and set data: 51.
3) Select page: 6, address: 01, set data: 51, and press the PAUSE
button of the adjustment remote commander.
4) Select page: 6, address: 02, and check that the data is 01.
5) Select page: 2, address: 00, and set data: 29.
6) Select page: 2, address: 01, set data: 29, and press the PAUSE
button of the adjustment remote commander.
7) Perform "Modification of D,E,F Page Data".

2. Modification of D, E, F Page Data

If the D, E, F page data has been initialized, change the data of the
"Fixed data-2" address shown in the following tables by manual
input.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the camcorder may
not operate.
3) When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
4) Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
5) After completing "Modification of D, E, F Page Data", select
page: 0, address: 01, and set data: 00. Also perform all
adjustments.
3. D Page Table
Note : Fixed data-1 : Initialized data. (Refer to "1. Initializing the D,E,F
Page Data".)
Fixed data-2 : Modified data. (Refer to "2. Modification of D, E, F
Page Data".)
Address
Initial value
00 to 0F
10
00
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
20
21
22
23
24
25
26
27
28
29
2A
2B
2C
2D
2E
2F
30
88
31
8D
32
A8
33
BD
34
C8
35
36
37
38
39
3A
3B
3C
3D
3E
3F
5-6
Remark
Test mode
Fixed data-1
(Initialized data)
Fixed data-2
(Modified data, copy the data built in
the same model.)
Fixed data-1
(Initialized data)
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
(Initialized data)
Fixed data-2
(Modified data, copy the data built in
the same model.)
Fixed data-1
Fixed data-2
(Modified data, copy the data built in
the same model.)
Battery end adj.
Fixed data-1
Fixed data-2
(Modified data, copy the data built in
the same model.)
Fixed data-1