DRAINAGE
Self-evaporating system
The self-evaporating system uses the collected water to cool the condenser
coils for more efficient performance. There is no need to empty the drainage
tank in cooling operation, only in heating operation, drying operation, and high
humidity conditions. The condensate water evaporates at the condenser and is
expunged through the exhaust hose.
For continuous operation or unattended operating in drying and heating
operation, please connect the attached drain hose to the unit. Condensate
water can be automatically drained into a bucket or drain by gravity.
• Switch off the unit before operating.
• Remove the plug of the water outlet
opening and keep it in safe area.
• Securely and properly connect the
drain hose and make sure it is not
kinked and clear of obstruction.
• Place the outlet of the hose over
a drain or bucket and ensure that
water can freely flow out of the unit.
• Do not submerge the end of hose
into water; otherwise it can cause
"Air Lock" in the hose.
To avoid water spillage:
• As the negative pressure of the condensate drain pan is large, tilt the drain
hose downward towards the floor. It is appropriate that the degree of
inclination should exceed 20 degrees.
• Straighten the hose to avoid any obstruction.
15429_Dimplex DPRC20ECO-A Manual.indd 17
15429_Dimplex DPRC20ECO-A Manual.indd 17
Remove the rubber
sealing plug.
Continuous
drain hose.
17