Page 1
INSTRUCTION MANUAL Portable Air Conditioner Model: DPRC29ECO-B For domestic household use only. 15429_Dimplex DPRC29ECO-B Manual.indd 1 15429_Dimplex DPRC29ECO-B Manual.indd 1 7/09/20 4:27 PM 7/09/20 4:27 PM...
Page 2
This product should not be used for commercial or industrial or leisure applications or in small enclosed spaces. • Never use the mains lead as a carrying strap or pulling lead. 15429_Dimplex DPRC29ECO-B Manual.indd 2 15429_Dimplex DPRC29ECO-B Manual.indd 2 7/09/20 4:27 PM...
Page 3
Gas Work Authorisation for hydrocarbon refrigerants to carry out servicing or repairs where the gas system is being opened or charged. • This appliance shall be installed in accordance with national wiring regulations. 15429_Dimplex DPRC29ECO-B Manual.indd 3 15429_Dimplex DPRC29ECO-B Manual.indd 3 7/09/20 4:27 PM 7/09/20 4:27 PM...
Page 4
Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants. 15429_Dimplex DPRC29ECO-B Manual.indd 4 15429_Dimplex DPRC29ECO-B Manual.indd 4 7/09/20 4:27 PM 7/09/20 4:27 PM...
Page 5
The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere. 15429_Dimplex DPRC29ECO-B Manual.indd 5 15429_Dimplex DPRC29ECO-B Manual.indd 5 7/09/20 4:27 PM 7/09/20 4:27 PM...
Page 6
NOTE: The use of silicon sealant may inhibit the effectiveness of some types of leak detection equipment. Intrinsically safe components do not have to be isolated prior to working on them. 15429_Dimplex DPRC29ECO-B Manual.indd 6 15429_Dimplex DPRC29ECO-B Manual.indd 6 7/09/20 4:27 PM...
Page 7
Ensure that the outlet for the vacuum pump is not close to any ignition sources and there is ventilation available. 15429_Dimplex DPRC29ECO-B Manual.indd 7 15429_Dimplex DPRC29ECO-B Manual.indd 7 7/09/20 4:27 PM...
Page 8
Equipment shall be labelled stating that it has been de-commissioned and emptied of refrigerant. The label shall be dated and signed. Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant. 15429_Dimplex DPRC29ECO-B Manual.indd 8 15429_Dimplex DPRC29ECO-B Manual.indd 8 7/09/20 4:27 PM...
Page 9
Only electric heating to the compressor body shall be employed to accelerate this process. When oil is drained from a system, it shall be carried out safely. 15429_Dimplex DPRC29ECO-B Manual.indd 9 15429_Dimplex DPRC29ECO-B Manual.indd 9 7/09/20 4:27 PM...
• Automatic restart in the event of power outage • Auto defrosting function at low ambient temperatures • Remote control • 2-speed fan • Casters for easy mobility 15429_Dimplex DPRC29ECO-B Manual.indd 10 15429_Dimplex DPRC29ECO-B Manual.indd 10 7/09/20 4:27 PM 7/09/20 4:27 PM...
Page 11
Note: The appearance is only for reference. Please see the real product for detailed information. Accessories: 1. Exhaust hose 2. Hose connector 3. Window kit adapter 4. Remote control 5. Window kit 15429_Dimplex DPRC29ECO-B Manual.indd 11 15429_Dimplex DPRC29ECO-B Manual.indd 11 7/09/20 4:27 PM 7/09/20 4:27 PM...
Do not replace or extend exhaust hose, this will result in decreased efficiency or even shut down the unit due to low backpressure. Step 1: Connect the hose connector to one end of the exhaust hose. 15429_Dimplex DPRC29ECO-B Manual.indd 12 15429_Dimplex DPRC29ECO-B Manual.indd 12 7/09/20 4:27 PM...
Page 13
Step 6: Adjust the length of the flexible exhaust hose (avoid bending the hose). Then place AC near an electrical outlet. Step 7: Adjust the louver at the air outlet, and then switch on the unit. 15429_Dimplex DPRC29ECO-B Manual.indd 13 15429_Dimplex DPRC29ECO-B Manual.indd 13 7/09/20 4:27 PM...
Press to switch the fan speed between HIGH and LOW Digital Display Displays timer setting and room temperature. Press to Increase the desired temperature or timer setting. 15429_Dimplex DPRC29ECO-B Manual.indd 14 15429_Dimplex DPRC29ECO-B Manual.indd 14 7/09/20 4:27 PM 7/09/20 4:27 PM...
Drying operation. User should connect the hose to the drain outlet at the bottom of the unit. Note: In this mode, the fan speed switches over to low speed and cannot be adjusted. 15429_Dimplex DPRC29ECO-B Manual.indd 15 15429_Dimplex DPRC29ECO-B Manual.indd 15 7/09/20 4:27 PM 7/09/20 4:27 PM...
Page 16
20 minutes, the unit will start defrosting for 5 minutes and the power indicator will blink. Overload Protection In the event of power loss, to protect the compressor there is a 3-minute delay before the compressor restarts. 15429_Dimplex DPRC29ECO-B Manual.indd 16 15429_Dimplex DPRC29ECO-B Manual.indd 16 7/09/20 4:27 PM 7/09/20 4:27 PM...
Page 17
• As the negative pressure of the condensate drain pan is large, tilt the drain hose downward towards the floor. It is appropriate that the degree of inclination should exceed 20 degrees. • Straighten the hose to avoid any obstruction. 15429_Dimplex DPRC29ECO-B Manual.indd 17 15429_Dimplex DPRC29ECO-B Manual.indd 17 7/09/20 4:27 PM 7/09/20 4:27 PM...
Pic 1. Switch off the unit and under running water. remove the two air filters. Warning!!! Do not touch the evaporator surface with bare hands, or it could injure your fingers. 15429_Dimplex DPRC29ECO-B Manual.indd 18 15429_Dimplex DPRC29ECO-B Manual.indd 18 7/09/20 4:27 PM 7/09/20 4:27 PM...
Page 19
7. Stop the source of the release, if safe to do so. Consider the use of water spray to disperse vapors. 8. Isolate the area until gas has dispersed. Ventilate and gas test area before entering. Contact competent authorities after a spill. 15429_Dimplex DPRC29ECO-B Manual.indd 19 15429_Dimplex DPRC29ECO-B Manual.indd 19 7/09/20 4:27 PM 7/09/20 4:27 PM...
• Coil temperature sensor failures. it. To clean or replace the temperature sensor. • Condensate water high level • Empty the drain pan by alarm. removal the rubber plug. 15429_Dimplex DPRC29ECO-B Manual.indd 20 15429_Dimplex DPRC29ECO-B Manual.indd 20 7/09/20 4:27 PM 7/09/20 4:27 PM...
Warranty Please refer to the warranty card in the box for warranty information. For any troubleshooting advice, please contact the relative Customer Care Centre below. Glen Dimplex Australia Pty Ltd Glen Dimplex New Zealand Ltd 1340 Ferntree Gully Road, 38 Harris Road, East Tamaki,...