Advertisement

INSTRUCTION MANUAL
Portable Air Conditioner
Model: DCPAC07C
For domestic household use only.

Advertisement

Table of Contents
loading

Summary of Contents for Dimplex DCPAC07C

  • Page 1 INSTRUCTION MANUAL Portable Air Conditioner Model: DCPAC07C For domestic household use only.
  • Page 2 IMPORTANT THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE. Note also the information presented on the appliance CAUTION: FAILURE TO FOLLOW THESE INSTRUCTIONS MAY CAUSE INJURY AND/OR DAMAGE AND MAY INVALIDATE YOUR WARRANTY Please read the operating instructions carefully before using your Portable Air Conditioner for the first time and keep them in a safe place.
  • Page 3 may lead to a risk of fire or electric shock. • Only operate this appliance with a minimum of 50cm clearance all around i.e. away from walls, furniture and overhanging objects such as curtains or a shelf. • WARNING: To avoid danger of suffocation please remove all packaging materials particularly plastic and EPS and keep these away from vulnerable people, children and babies.
  • Page 4 WARNING: For using R290 refrigerant. ThIs symbol shows that this appliance uses a flammable refrigerant. If the refrigerant is leaked and exposed to an external ignition source, there is a risk of fire. CAUTION: RISK OF FIRE/FLAMMABLE MATERIALS. THE APPLIANCE MUST BE INSTALLED, USED &...
  • Page 5 1. Transport of equipment containing flammable refrigerants - see transport regulations 2. Marking of equipment using signs - see local regulations 3. Disposal of equipment using flammable refrigerants - see national regulations. 4. Storage of equipment/appliances - The storage of equipment should be in accordance with the manufacturer's instructions.
  • Page 6 • Checks to the refrigeration equipment Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the manufacturer's maintenance and service guidelines shall be followed. If in doubt consult the manufacturer's technical department for assistance.
  • Page 7 • Repair to intrinsically safe components Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that this will not exceed the permissible voltage and current permitted for the equipment in use. Intrinsically safe components are the only types that can be worked on while live in the presence of a flammable atmosphere.
  • Page 8 • Charging procedures In addition to conventional charging procedures, the following requirements shall be followed. Ensure that contamination of different refrigerants does not occur when using charging equipment. Hoses or lines shall be as short as possible to minimise the amount of refrigerant contained in them. Cylinders shall be kept upright.
  • Page 9 • Recovery When removing refrigerant from a system, either for servicing or decommissioning, it is recommended good practice that all refrigerants are removed safely. When transferring refrigerant into cylinders, ensure that only appropriate refrigerant recovery cylinders are employed. Ensure that the correct number of cylinders for holding the total system charge is available.
  • Page 10 Exposed to the Near water If the power cable weather outdoors wires are frayed or cut Where small children If an extension Where the power may be left unattended lead may become cable may be overloaded damaged On a slope or Where there is risk Where it may be uneven surface...
  • Page 11: Specification

    Specification Model no. DCPAC07C Colour White Power supply 220-240V~, 50Hz Operating temperature 18-35°C Thermostat range 18-32°C Rated Input Power 830W Cooling Capacity 2.05kW Dehumidification Capacity 1.8L/hour Noise Level Minimum (Lo) 62dB(A) Noise Level Maximum (Hi) 64dB(A) Air Volume (Hi/Lo) 225/200m³/h...
  • Page 12 Parts 1. Control panel 2. Handles (both sides) 3. Castors 4. Louvres 5. Air intake grille 6. Air outlet 7. Air intake grille 8. Power cord 9. Plug/cord storage 10. Middle drain/plug 11. Lower drain/plug 12. Remote control storage 1 x Exhaust hose kit 1 x Window slider (with hole) 1 x Remote control 1 x Window slider (without hole)
  • Page 13: Control Panel

    Control Panel 1. Timer button A. Cool indicator 2. Fan speed button B. Dry/dehumidify indicator 3. Increase button (+) C. Fan indicator 4. LED display screen D. High speed indicator 5. Decrease button (-) E. Low speed indicator 6. Mode button F.
  • Page 14: Exhaust Hose Installation

    Installation PREPARATION NOTE: All the illustrations in the manual are for explanatory purposes only. Your machine may be slightly different. The unit can be controlled by the control panel or with the remote control. EXHAUST HOSE INSTALLATION The exhaust hose and adaptor must be installed or removed in accordance with the set MODE.
  • Page 15 Installation EXHAUST HOSE INSTALLATION 1. Extend either side of the hose (Fig. 1) 2. Screw the hose to the inlet attachment (Fig. 2) 3. Screw the hose to the outlet attachment (Fig. 3) 4. Install the hose inlet into the unit (Fig. 4) 5.
  • Page 16: Window Kit Installation

    Installation WINDOW KIT INSTALLATION Part Names A) Panel B) Panel with one hole D) Screws to lock window kit in place Window Kit Assembly • Slide Panel B into Panel A and size to window width. Windows sizes will vary. When sizing the window width, be sure that the window kit assembly is free from gaps from gaps and/or air pockets when taking measurements.
  • Page 17: Cool Mode

    Functions ON/OFF Press to turn the unit on/off. LED display The LED displays indicates the timer setting or set temperature. When the set temperate or the timer is adjusted, the new setting is shown on the display. The LED display is also used to show error codes should a fault occur. COOL MODE 1.
  • Page 18: Sleep Mode

    Functions SLEEP MODE • The SLEEP MODE maintains the optimum room temperature without excessive fluctuations in either temperature or humidity and with quieter operation. • Fan speed is always LOW, while room temperature and humidity vary gradually to ensure the most comfortable nights sleep. •...
  • Page 19: Error Codes

    Error Codes ERROR CODES Lt - Low Temperature Error The unit is fitted with a frost protection device to avoid excessive formation of ice. The unit will start automatically once the defrosting process is complete. PF - Probe Failure Error If this is displayed, contact customer service or your local authorised service centre.
  • Page 20 Water Drainage WATER DRAINAGE NOTE Please be sure that the drain hose is not higher than that of the drain outlet, or the water may not drain properly. (See diagram 26 & 27) MIDDLE DRAINAGE When the unit is running in Dry/Dehumidfy mode, you can choose middle drainage as a way of continuous drainage.
  • Page 21 Remote Control Using the Remote Control 1. Open the battery cover of the remote control, and insert 2 x AAA batteries. 2. Please point to the receiver and be within 7m when using the remote control. 3. If the battery voltage is low, please open the battery cover as per the diagram and replace with a new batteries (2 x AAA).
  • Page 22: Safety Precautions

    Cleaning SAFETY PRECAUTIONS • Always unplug the unit before cleaning or servicing. • DO NOT use flammable liquids or chemicals to clean the unit. • DO NOT wash the unit under running water. Doing so causes electrical danger. • DO NOT operate the machine if the power supply was damaged during cleaning. A damaged power cord must be replaced with a new cord from the manufacturer.
  • Page 23: Maintenance

    Warranty Please refer to the warranty card in the box for warranty information. For any troubleshooting advice, please contact the relative Customer Care Centre below. Glen Dimplex Australia Pty Ltd Glen Dimplex New Zealand Ltd 1340 Ferntree Gully Road, 38 Harris Road, East Tamaki,...
  • Page 24 Supplied by Glen Dimplex Australia 1340 Ferntree Gully Road, Scoresby, Victoria, 3179 © Glen Dimplex Australia. All rights reserved. Material contained in this publication may not be reproduced in whole or in part, without prior permission in writing of Glen Dimplex Australia.

Table of Contents