Advertisement

Quick Links

INSTRUCTION MANUAL
Portable Air Conditioner
Model: DPRC41ECO-C
For domestic household use only.
15429_Dimplex DPRC41ECO-C Manual.indd 1
15429_Dimplex DPRC41ECO-C Manual.indd 1
7/09/20 4:24 PM
7/09/20 4:24 PM

Advertisement

Table of Contents
loading

Summary of Contents for Dimplex DPRC41ECO-C

  • Page 1 INSTRUCTION MANUAL Portable Air Conditioner Model: DPRC41ECO-C For domestic household use only. 15429_Dimplex DPRC41ECO-C Manual.indd 1 15429_Dimplex DPRC41ECO-C Manual.indd 1 7/09/20 4:24 PM 7/09/20 4:24 PM...
  • Page 2 This product should not be used for commercial or industrial or leisure applications or in small enclosed spaces. • Never use the mains lead as a carrying strap or pulling lead. 15429_Dimplex DPRC41ECO-C Manual.indd 2 15429_Dimplex DPRC41ECO-C Manual.indd 2 7/09/20 4:24 PM...
  • Page 3 Gas Work Authorisation for hydrocarbon refrigerants to carry out servicing or repairs where the gas system is being opened or charged. • This appliance shall be installed in accordance with national wiring regulations. 15429_Dimplex DPRC41ECO-C Manual.indd 3 15429_Dimplex DPRC41ECO-C Manual.indd 3 7/09/20 4:24 PM 7/09/20 4:24 PM...
  • Page 4 Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants. 15429_Dimplex DPRC41ECO-C Manual.indd 4 15429_Dimplex DPRC41ECO-C Manual.indd 4 7/09/20 4:24 PM 7/09/20 4:24 PM...
  • Page 5 The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere. 15429_Dimplex DPRC41ECO-C Manual.indd 5 15429_Dimplex DPRC41ECO-C Manual.indd 5 7/09/20 4:24 PM 7/09/20 4:24 PM...
  • Page 6 NOTE: The use of silicon sealant may inhibit the effectiveness of some types of leak detection equipment. Intrinsically safe components do not have to be isolated prior to working on them. 15429_Dimplex DPRC41ECO-C Manual.indd 6 15429_Dimplex DPRC41ECO-C Manual.indd 6 7/09/20 4:24 PM...
  • Page 7 Ensure that the outlet for the vacuum pump is not close to any ignition sources and there is ventilation available. 15429_Dimplex DPRC41ECO-C Manual.indd 7 15429_Dimplex DPRC41ECO-C Manual.indd 7 7/09/20 4:24 PM...
  • Page 8 Equipment shall be labelled stating that it has been de-commissioned and emptied of refrigerant. The label shall be dated and signed. Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant. 15429_Dimplex DPRC41ECO-C Manual.indd 8 15429_Dimplex DPRC41ECO-C Manual.indd 8 7/09/20 4:24 PM...
  • Page 9 Only electric heating to the compressor body shall be employed to accelerate this process. When oil is drained from a system, it shall be carried out safely. 15429_Dimplex DPRC41ECO-C Manual.indd 9 15429_Dimplex DPRC41ECO-C Manual.indd 9 7/09/20 4:24 PM...
  • Page 10: Specification

    • Automatic restart in the event of power outage • Auto defrosting function at low ambient temperatures • Remote control • 3-speed fan • Casters for easy mobility 15429_Dimplex DPRC41ECO-C Manual.indd 10 15429_Dimplex DPRC41ECO-C Manual.indd 10 7/09/20 4:24 PM 7/09/20 4:24 PM...
  • Page 11 Check the device after unpacking for any damage or scratches on it. Accessories: 1. Exhaust hose 2. Hose connector 3. Window kit adapter 4. Remote control 5. Window kit 15429_Dimplex DPRC41ECO-C Manual.indd 11 15429_Dimplex DPRC41ECO-C Manual.indd 11 7/09/20 4:24 PM 7/09/20 4:24 PM...
  • Page 12: Installation Instructions

    Do not replace or extend exhaust hose, this will result in decreased efficiency or even shut down the unit due to low backpressure. Step 1: Connect the hose connector to one end of the exhaust hose. 15429_Dimplex DPRC41ECO-C Manual.indd 12 15429_Dimplex DPRC41ECO-C Manual.indd 12 7/09/20 4:24 PM...
  • Page 13 Step 6: Adjust the length of the flexible exhaust hose (avoid bending the hose). Then place AC near an electrical outlet. Step 7: Adjust the louver at the air outlet, and then switch on the unit. 15429_Dimplex DPRC41ECO-C Manual.indd 13 15429_Dimplex DPRC41ECO-C Manual.indd 13 7/09/20 4:24 PM...
  • Page 14: Parts And Features

    Displays timer setting and room temperature. 10. Up Press to Increase the desired temperature or timer setting. SLEEP Press to turn sleep mode on or off. 15429_Dimplex DPRC41ECO-C Manual.indd 14 15429_Dimplex DPRC41ECO-C Manual.indd 14 7/09/20 4:24 PM 7/09/20 4:24 PM...
  • Page 15: Startup And Shutdown

    Drying operation. User should connect the hose to the drain outlet at the bottom of the unit. Note: In this mode, the fan speed switches over to low speed and cannot be adjusted. 15429_Dimplex DPRC41ECO-C Manual.indd 15 15429_Dimplex DPRC41ECO-C Manual.indd 15 7/09/20 4:24 PM 7/09/20 4:24 PM...
  • Page 16 20 minutes, the unit will start defrosting for 5 minutes and the power indicator will blink. Overload Protection In the event of power loss, to protect the compressor there is a 3-minute delay before the compressor restarts. 15429_Dimplex DPRC41ECO-C Manual.indd 16 15429_Dimplex DPRC41ECO-C Manual.indd 16 7/09/20 4:24 PM 7/09/20 4:24 PM...
  • Page 17 • As the negative pressure of the condensate drain pan is large, tilt the drain hose downward towards the floor. It is appropriate that the degree of inclination should exceed 20 degrees. • Straighten the hose to avoid any obstruction. 15429_Dimplex DPRC41ECO-C Manual.indd 17 15429_Dimplex DPRC41ECO-C Manual.indd 17 7/09/20 4:24 PM 7/09/20 4:24 PM...
  • Page 18: Cleaning And Care

    Pic 1. Switch off the unit and under running water. remove the two air filters. Warning!!! Do not touch the evaporator surface with bare hands, or it could injure your fingers. 15429_Dimplex DPRC41ECO-C Manual.indd 18 15429_Dimplex DPRC41ECO-C Manual.indd 18 7/09/20 4:24 PM 7/09/20 4:24 PM...
  • Page 19 7. Stop the source of the release, if safe to do so. Consider the use of water spray to disperse vapors. 8. Isolate the area until gas has dispersed. Ventilate and gas test area before entering. Contact competent authorities after a spill. 15429_Dimplex DPRC41ECO-C Manual.indd 19 15429_Dimplex DPRC41ECO-C Manual.indd 19 7/09/20 4:24 PM 7/09/20 4:24 PM...
  • Page 20: Troubleshooting

    • Coil temperature sensor failures. it. To clean or replace the temperature sensor. • Condensate water high level • Empty the drain pan by alarm. removal the rubber plug. 15429_Dimplex DPRC41ECO-C Manual.indd 20 15429_Dimplex DPRC41ECO-C Manual.indd 20 7/09/20 4:24 PM 7/09/20 4:24 PM...
  • Page 21 If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the ground water, polluting the food chain and damaging health and well-being. 15429_Dimplex DPRC41ECO-C Manual.indd 21 15429_Dimplex DPRC41ECO-C Manual.indd 21 7/09/20 4:24 PM 7/09/20 4:24 PM...
  • Page 22 15429_Dimplex DPRC41ECO-C Manual.indd 22 15429_Dimplex DPRC41ECO-C Manual.indd 22 7/09/20 4:24 PM 7/09/20 4:24 PM...
  • Page 23: Maintenance

    Warranty Please refer to the warranty card in the box for warranty information. For any troubleshooting advice, please contact the relative Customer Care Centre below. Glen Dimplex Australia Pty Ltd Glen Dimplex New Zealand Ltd 1340 Ferntree Gully Road, 38 Harris Road, East Tamaki,...
  • Page 24 38 Harris Road, East Tamaki, Auckland 2013 © Glen Dimplex New Zealand Ltd. All rights reserved. Material contained in this publication may not be reproduced in whole or in part, without prior permission in writing of Glen Dimplex New Zealand Ltd.

Table of Contents