SPORT ELEC Body Beautiful User Manual page 118

Hide thumbs Also See for Body Beautiful:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 12
The Body Beautiful is intended for use in the electromagnetic environment specified below. The customer or the user of
the Body Beautiful should assure that it is used in such an environment.
IMMUNITY
IEC 60601
TEST
TEST LEVEL
3 Vrms
Conducted RF IEC
61000-4-6
150 kHz to 80 MHz
3 V/m
Radiated RF IEC
61000-4-3
80 MHz to 2.5 GHz
NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations.
Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.
a. Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio,
AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due
to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the Body
Beautiful is used exceeds the applicable RF compliance level above, the Body Beautiful should be observed to verify normal operation. If abnormal
performance is observed, additional measures may be necessary, such as re-orienting or relocating the Body Beautiful.
b. Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.
RECOMMENDED SEPARATION DISTANCES BETWEEN PORTABLE AND MOBILE RF
f
f
TThe Body Beautiful is intended for use in an electromagnetic environment in which radiated RF disturbances are
controlled. The customer or the user of Body Beautiful can help prevent electromagnetic interference by maintaining a
minimum distance between portable and mobile RF communications equipment (transmitters) and the Body Beautiful as
recommended below, according to the maximum output power of the communications equipment..
RATED MAXIMUM OUTPUT
POWER OF TRANSMITTER
(W)
0.01
0.1
1
10
100
For transmitters rated at a maximum output power not listed above, the recommended separation distance d in metres (m) can be estimated using the
equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the
transmitter manufacturer.
NOTE 1 At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects
and people
GUIDANCE AND MANUFACTURER'S DECLARATION
f
f
ELECTROMAGNETIC IMMUNITY
COMPLIANCE
LEVEL
Portable and mobile RF communications equipment should be used
no closer to any part of the Body Beautiful, including cables, than the
recommended separation distance calculated from the equation applicable to
3 Vrms
where P is the maximum output power rating of the transmitter in watts
(W) according to the transmitter manufacturer and d is the recommended
determined by an electromagnetic site survey,a should be less than the
3 V/m
Interference may occur in the vicinity of equipment marked with the following
COMMUNICATIONS EQUIPMENT AND THE FREE ACTION
SEPARATION DISTANCE ACCORDING TO FREQUENCY OF TRANSMITTER (M)
150 KHZ TO 80 MHZ
80 MHZ TO 800 MHZ
d = 1.17
d = 1.17
0.117
0.117
0.369
0.369
1.167
1.167
3.690
3.690
11.67
11.67
ELECTROMAGNETIC ENVIRONMENT – GUIDANCE
the frequency of the transmitter.
Recommended separation distance
d=1.67√P
d=1.67√P 80 MHz to 800 MHz
d=2.333√P 800MHz to 2,5 GHz
separation Distance in metres (m).
Field strengths from fixed RF transmitters, as
compliance level in each frequency range.b
symbol:
800 MHZ TO 2.5 GHZ
d = 2.33
0.233
0.738
2.333
7.377
23.33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bb2m

Table of Contents