Alternatively, the Switch can be rack-mounted in a
wiring closet or equipment room. A mounting kit,
containing two mounting brackets and four screws, is
supplied with the Switch.
When deciding where to position the Switch, ensure
that:
It is accessible and cables can be connected easily.
Cabling is away from sources of electrical noise.
These include lift shafts, microwave ovens, and air
conditioning units. Electromagnetic fields can
interfere with the signals on copper cabling and
introduce errors, therefore slowing down your
network.
Water or moisture cannot enter the case of the unit.
Air flow around the unit and through the vents on
the side of the case is not restricted (3Com
recommends that you provide a minimum of 25 mm
(1 in.) clearance).
The air is as free from dust as possible.
Temperature operating limits are not likely to be
exceeded. It is recommended that the unit is installed
in a clean, air conditioned environment.
It is always good practice to wear an anti-static wrist
strap when installing network equipment, connected to
a ground point. If one is not available, try to keep in
contact with a grounded rack and avoid touching the
unit's ports and connectors, if possible. Static discharge
can cause reliability problems in your equipment.

Rack-Mounting or Free-Standing

The unit can be mounted in a 19-inch equipment rack
using the mounting kit or it can be free standing. Do
not place objects on top of the unit or stack.
CAUTION: If installing the Switch in a free-standing
stack of different size Baseline or Superstack 3 units, the
smaller units must be installed above the larger ones.
Do not have a free-standing stack of more than six
units.

Using the Mounting Kit

The Switch is supplied with two mounting brackets and
four screws. These are used for rack mounting the unit.
When mounting the unit, you should take note of the
guidelines given in "Positioning the Switch" on
page 15.
The Switch is 1U (1.7 inches) high and will fit in a
standard 19-inch rack.
CAUTION: Disconnect all cables from the unit before
continuing. Remove the self-adhesive pads from the
underside of unit, if already fitted.
To rack-mount the Switch:
Place the unit the right way up on a hard, flat surface
1
with the front facing towards you.
Locate a mounting bracket over the mounting holes on
2
one side of the unit.