■ Error Code 4900
Head voltage does not raise.
< User Check >
- They may occur due to lower surrounding temperature. Use in warmer surrounding
temperature.
Step
1
Head flat cable connection
failure
2
Carriage flat cable connection
failure
3
Carriage PCB defective
4
Head defective
5
Power supply PCB defective
6
Main PCB defective
■ Error Code 4C00
ASIC thermistor error.
- The ASIC thermistor detected a temperature of -21 degree-C or less, or 125
degree-C or greater, when the machine was turned on.
Error Code 4C01
Compound IC thermistor error.
- The compound IC thermistor detected a temperature of -21 degree-C or less, or
125 degree-C or greater, when the machine was turned on.
Step
1
Head flat cable connection failure
2
Carriage flat cable connection
failure
3
Carriage PCB defective
4
Head defective
5
Power supply PCB defective
6
Main PCB defective
■ Error Code 4E00
Head voltage remains ON and does not turn OFF even after 15 minutes have
passed.
Step
1
Carriage PCB defective
2
Head defective
3
Main PCB defective
Cause
Reconnect the head flat cable.
Reconnect the carriage flat cable.
Replace the carriage PCB ASSY.
Replace the head/carriage unit.
Replace the power supply PCB.
Replace the main PCB.
Cause
Cause
Replace the carriage PCB ASSY.
Replace the head/carriage unit.
Replace the main PCB.
2-39
Solution
Solution
Reconnect the head flat cable.
Reconnect the carriage flat cable.
Replace the carriage PCB ASSY.
Replace the head/carriage unit.
Replace the power supply PCB.
Replace the main PCB.
Solution