Solenoid Valve Repair Kit - Jackson Conserver XL2 Series Installation, Operation And Service Manual

Hide thumbs Also See for Conserver XL2 Series:
Table of Contents

Advertisement

PARTS
Complete 110 Volt Solenoid Valve Assembly
115
04810-100-53-00
Coil & Housing only
04810-200-01-18
Complete 240 Volt Solenoid Valve Assembly
230
04810-100-03-18
Coil & Housing only
04810-200-02-18
Possible Problems:
1. Pilot port extension #1 clogged. Clean hole.
2. Hole #2 Clogged. Pass heated straight pin through hole.
1
07610-002-10-23-U

SOLENOID VALVE REPAIR KIT

Data Plate
Valve Bonnet
Diaphragm
Retainer
Screen
Retainer
Valve Body
2
Screw
Coil & Housing
Spring
06401-003-07-40
Spring & Plunger
05700-003-07-40
Plunger
06401-003-07-40
O-Ring
06401-003-07-42
O-ring & Diaphragm
05700-003-07-42
Diaphragm
06401-003-07-42
Mesh Screen
TO TAKE THE SOLENOID VALVE APART
DISASSEMBLY - These valves may be taken apart by
unscrewing the bonnet and the enclosing tube assembly from
the valve body assembly. After unscrewing, carefully lift off the
bonnet and enclosing tube assembly. Don't drop the plunger.
The o-ring seal and diaphragm cartridge can now be lifted out.
Be careful not to damage the machined faces while the valve
is apart.
TO REASSEMBLE - Place the diaphragm cartridge in the
body with the pilot port extension UP. Hold the plunger with the
synthetic seat against the pilot port. Make sure the o-ring is in
place, then lower the bonnet and enclosing tube assembly
over the plunger. Screw the bonnet assembly snugly down on
the body assembly.
40