Toro Greensmaster TriFlex 3300 Operator's Manual page 40

Traction unit
Hide thumbs Also See for Greensmaster TriFlex 3300:
Table of Contents

Advertisement

Figure 39
Before Starting (fluid cold)
1. Filler plug
2. Filler neck
3. Overflow tube
4. Leak-detector tank
Figure 40
Normal Operation (fluid warm)
1. Fluid level (warm)
2. Solenoid-return valve
(closed)
g229108
5. Warning buzzer—no
sound
6. Fluid level (cold)
7. Solenoid-return valve
(open)
8. Float switch
(raised—open)
g229109
3. Warning buzzer
4. Float switch
(raised—open)
1. Float switch
(down—closed)
Fluid level down 118
to 177 ml (4 to 6 oz)
2. Warning buzzer
Checking the System Operation
1.
With ignition switch in the O
leak detector switch rearward and hold. After
the 1-second delay elapses, the alarm should
sound.
2.
Release the leak-detector switch.
Checking the
Leak-Detector-System Operation
1.
Move the ignition switch to the O
not start the engine.
2.
Remove the hydraulic-tank cap from the neck
of the tank.
3.
Insert a clean rod or screwdriver into the tank
neck and gently push down on the float switch
(Figure
42); the alarm should sound after the
1-second delay.
40
Figure 41
Leak Alert!
3. Fluid level (warm)
position, move the
N
position. Do
N
g229110