6 Technical data
Pressure/temperature
correlation:
Leakage rate:
Kv values:
6.4 Product compliance
Machinery Directive:
Food:
6.5 Mechanical data
Protection class:
Weight:
Operating time:
Cycle duties:
GEMÜ F60
Hot water, steam
9
8
7
6
5
4
3
2
1
0
80
90
Hot water
Steam
Seat seal
Standard
EPDM, FPM, PTFE
DIN EN 12266-1
DN
Code
10
17
15
17
Kv values in m³/h
2006/42/EU
FDA
USP Class VI
Regulation (EC) No. 1935/2004
Regulation (EC) No. 10/2011
EHEDG certified
Actuator and cable exit: IP69K acc. to EN 60529
Connector plug: IP65/IP67 acc. to EN 60529 when plugged in
Actuator size 3
Body
Spigot
Clamp
adjustable, max. 200 mm/s
Cycle duties (over 10 million)
The cycle duties depend on the operating parameters. High pressures and media temperatures
can lead to a shorter service life.
100
110
Temperature [°C]
max. 4 bar at 140 °C, max. 60 min
max. 2 bar at 140 °C, max. 60 min
Test procedure
P12
Flow direction
over the seat [1 → 2]
2.7 m³/h
6.1 m³/h
Valve assembly approx. 2,300 g
0.30 kg
0.22 kg
10 / 24
Steam
Hot water
120
130
140
Leakage rate
A
Flow direction
under the seat [2 → 1]
2.8 m³/h
6.6 m³/h
www.gemu-group.com
150
Test medium
Air