Pipework / Filling The System / Safety Datasheet - Wolf CFK-1 Installation, Operating And Maintenance Instructions

Rooftop installation with aluplus installation system, roof integration flat roof installation with aluplus installation system. high performance solar collector.
Table of Contents

Advertisement

Information regarding the
system hydraulics
Pipework and sensor
installation
Pipework
Collector sensor 6 mm
Sensor well ¾"
Flow connection piece
Filling the system
Extract from the safety datasheet:
Trade name:
Company:
Emergency information:
Chemical properties:
Special safety information where there is a
risk of injury or damage to the environment.
After contact with eyes:
After skin contact:
After ingestion:
Transport:
Risk to water category:
38
17. Pipework / Filling the system /
Safety datasheet
-
Connect the collectors alternately across (up to 10 collectors side by side).
-
In the idle state, the lines near the collectors reach high temperatures.
-
For that reason, only use the gaskets supplied.
-
Use only temperature-resistant insulation material (> 175
areas insulation must also be UV and weather-resistant.
- Never use zinc-plated/galvanized pipes, fittings etc.
- Install flow and return lines without air locks or install manual air vent
valves.
- Install an air vent trap at the highest point in the flow riser.
Note: If the solar lines have not already been installed, route them from the
collector array to the intended connection point to enable the tightness to be
checked before the casing parts are fitted.
Air trap
>2cm/m
For flushing and filling the solar thermal system, we recommend the use of a
fill & flush pump that runs for at least 30 to 60 minutes. This makes manual
venting superfluous.
Info
Only ready-mixed ANRO in accordance with the specification is permissible.
ANRO heat transfer medium (ready-mixed, protection down to –30 °C)
Wolf GmbH, Postfach 1380, D-84048 Mainburg, Germany; Tel.: +49 8751/74-0;
Fax.:+49 8751/741600 +49(0)40509497-0
1.2 propyleneglycol with corrosion inhibitors,
45.3% by vol. mixed with 54.7% by vol. potable water, dyed blue
Not required
Flush with clear running water for 15 minutes whilst holding the eyelids apart.
Wash with water and soap.
Flush mouth and drink plenty of water.
Not dangerous cargo in the sense of the transport regulations
WGK1; little danger to water.
1 collector
Return connector
+ pipework for
roof integration
>2cm/m
o
C), in external
Pipework for rooftop /
flat roof installation
3062815_0110

Advertisement

Table of Contents
loading

Table of Contents