Figure 71 Menu 4 Internet Access Setup

The following table contains instructions on how to configure your Prestige for Internet
access.
Menu 4 Internet Access Setup
Table 43
FIELD
ISP's Name
Encapsulation
Multiplexing
VPI #
VCI #
ATM QoS Type
Peak Cell Rate
(PCR)
Sustain Cell Rate
(SCR)
Maximum Burst
Size (MBS)
My Login
Chapter 17 Internet Access
Menu 4 - Internet Access Setup
ISP's Name= MyISP
Encapsulation= RFC 1483
Multiplexing= LLC-based
VPI #= 8
VCI #= 35
ATM QoS Type= CBR
Peak Cell Rate (PCR)= 0
Sustain Cell Rate (SCR)= 0
Maximum Burst Size (MBS)= 0
My Login= N/A
My Password= N/A
ENET ENCAP Gateway= N/A
IP Address Assignment= Static
IP Address= 0.0.0.0
Network Address Translation= SUA Only
Address Mapping Set= N/A
Press ENTER to Confirm or ESC to Cancel:
DESCRIPTION
Enter the name of your Internet Service Provider (ISP). This information is for
identification purposes only.
SPACE BAR
Press [
] to select the method of encapsulation used by your ISP.
Choices are PPPoE, PPPoA, RFC 1483 or ENET ENCAP.
SPACE BAR
Press [
] to select the method of multiplexing used by your ISP.
Choices are VC-based or LLC-based.
Enter the Virtual Path Identifier (VPI) assigned to you.
Enter the Virtual Channel Identifier (VCI) assigned to you.
Press [SPACE BAR] and select CBR (Continuous Bit Rate) to specify fixed
(always-on) bandwidth. Select UBR (Unspecified Bit Rate) for applications that are
non-time sensitive, such as e-mail. Select VBR (Variable Bit Rate) for bursty traffic
and bandwidth sharing with other applications.
This is the maximum rate at which the sender can send cells. Type the PCR.
Sustained Cell Rate is the mean cell rate of a bursty, on-off traffic source that can
be sent at the peak rate, and a parameter for burst-traffic. Type the SCR; it must be
less than the PCR.
Refers to the maximum number of cells that can be sent at the peak rate. Type the
MBS. The MBS must be less than 65535.
Configure the My Login and My Password fields for PPPoA and PPPoE
encapsulation only. Enter the login name that your ISP gives you. If you are using
PPPoE encapsulation, then this field must be of the form user@domain where
domain identifies your PPPoE service name.