14.0 - ADDITION OF NEW DEVICES

To carry out the operation successfully, make sure the required electrical connections
!
(bonnet push-button and positive under key) are complete.
To activate the procedure proceed as follows:
!
With system disarmed, open the bonnet and leave it open
The following operations must be carried out within four seconds otherwise the
!
!
Turn ignition key "ON-OFF"-"ON-OFF"-"ON-OFF"-"ON"; at the fourth rotation, leave it "ON".
!
To confirm it has entered in the self-learning mode, the system gives two acoustic signals (one high
and one low-pitched), the turn indicators flash once and the LED turns ON
Do not close the bonnet otherwise all previously programmed devices are erased as
!
described in the next paragraph.
!
Insert the electronic key into the receptacle; each time a device is learned a high-pitched signal
sounds and the status LED turns OFF briefly.
! R
epeat this procedure to store other devices.
!
Turn ignition key "OFF"; t
he end of the procedure is indicated by
turn indicators flash once and the status LED turns OFF
Storing memory is for 55 devices; saving to memory the 56th. device has as a result the
!
deletion of the first device installed in the location one of the alarm memory.

15.0 - DELETION OF PROGRAMMED DEVICES

To carry out the operation successfully, make sure the required electrical connections
!
(bonnet push-button and positive under key) have been made.
All device previously programmed in the memory can be erased; to clear memory proceed as follows:
!
With system disarmed, open and keep opened the vehicle bonnet
The following operations must be carried out within four seconds otherwise the
!
!
Turn ignition key "ON-OFF"-"ON-OFF"-"ON-OFF"-"ON"; after the fourth rotation, leave it "ON".
!
To confirm it has entered in the delete mode, the system gives two acoustic signals (one high and
one low-pitched), the turn indicators flash once and the LED turns ON
!
Close the bonnet and k
eep it closed (approx. 8 sec.) until the devices are completely deleted
If the bonnet is opened before 8 seconds, the devices will not be
!
!
The status LED turns OFF when the devices have been deleted; turn ignition key "OFF
!
The end of the procedure is indicated by one long low-pitched acoustic signal
PAGE 14 - INSTALLER MANUAL
.
procedure is invalidated.
.
a low-pitched signal sounds, the
.
.
procedure is invalidated.
.
deleted.
.
I
nsert the WHITE connector in the "W" marked socket and the RED connector in the "R" marked
socket (see figure below).
Install the transducers of the ultrasonic sensors on the top part of the windscreen internal pillars, away
from the air vents and orient them towards the center of the rear window
To check sensitivity level proceed as follows
!
With the alarm system disarmed, roll down the front window about 20 cm.
!
Adjust trimmer at a medium setting.
!
Close all doors, bonnet and boot and arm the system.
!
During the system inhibit arming time introduce an object in the cabin through the window and
move it around; the status LED will turn off to signal a presence.
!
If sensitity lelvel is too high or too low, readjust the trimmer and repeat the above procedure
SENSITIVITY
ADJUSTMENT
By activating the following procedure, the system returns to the Factory default setting.
!
This procedure must therefore only be used in case of need, before programming the
To reset the system proceed as follows:
!
Switch-off
system
!
S
hort-circuit the RED and BLACK wires of the 2-way
!
Switch the
system
indicators will flash 4 times
!
Remove the previously created short-circuit; the status LED lights up steady.
!
Turn ignition key "ON";
approx. 3 seconds
!
Turn ignition key "OFF";
.
".
16.0 - U
LTRASONIC VOLUMETRIC PROTECTION

16.1 - CONNECTIONS AND POSITIONING

16.2 - SENSOR ADJUSTMENT

:

17.0 - SYSTEM RESET

system or auto-learning the turn indicators flashes.
power supply
.
LED
connector
on; once the alarm system is powered, 4 acoustic signals will sound and the turn
.
reset is confirmed by an aucoustic signal and the wailing of the siren for
.
the LED will turns off. There are no acoustic signals
.
.
ULTRASONIC
CELLS
CONNECTIONS
.
.