Ambient And Operating Conditions - Fagor QC-PDS Hardware Manual

Hide thumbs Also See for QC-PDS:
Table of Contents

Advertisement

1.6

Ambient and Operating Conditions

Terms
Mechanical specifications
Shipping
Operation
Ambient conditions
Storage *
Shipping *
Operation
* The shipping and storage environment must be dry and dust free.
** Open IP xx , to be installed inside a cabinet or assembly that provides the required access
protection.
Regulation
Vibration
Meets:
IEC 60721-3-2
Jerk limit
Meets:
IEC 60721-3-2
IEC 61800-2
Ambient sinusoidal
Meets:
vibration tests
CEI 60068-2-6,
Fc test
Degrees of sealing
Meets:
protection
EN 60529
(code IP)
Ambient
Meets:
temperature
IEC 60721-3-1
IEC 61800-2
Damp heat test
Meets:
(stationary state)
IEC 60068-2-78
IEC 61800-5-1
Ambient
Meets:
IEC 60068-2-1
temperature
IEC 61800-2
Ambient test.
Meets:
Cold
CEI 61800-2
Ambient test.
Meets:
Dry heat
IEC 60068-2-2,
Bd test
Meets:
Damp heat test
IEC 60068-2-78
(stationary state)
IEC 61800-5-1
Installation altitude
Meets:
over average
IEC 61800-5-1
sea level without
IEC 60664-1
derating
Test reference
Class 2M1, sinusoidal vibration
2 Hz f  9 Hz, 3.5 mm amplitude
9 Hz f  200 Hz, 1 g
200 Hz f  500 Hz, 1.5 g
Class 2M1,
packed unit
Sinusoidal vibration
10 Hz f  57 Hz,
constant 0.075 mm amplitude
57 Hz f  150 Hz,
1 g constant acceleration
Open IP xx.**
Always install inside
an electrical cabinet
1K4,
From -25 ºC to +60 ºC
Disconnected power supply
40ºC +/-2ºC and
93 % +2-3 % without condensation
Packed
unit
-40 °C to +70 ºC
5 ºC in running
conditions
Under nominal conditions of 45 °C.
Under running conditions between
5 ºC and 55 ºC with derating (see
derating characteristic).
Disconnected power supply. 40 ºC
+/-2 ºC
93 % +2-3 % non-condensing
Pollution degree 2
and altitude of  2000 amsl under
nominal conditions
  Description
1.
QC-PDS
HARDWARE
Ref.2003
· 37 ·

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents