Duty Cycle And Overheating; Volt-Ampere Curves - Hobart Handler 140 Technical Manual

Hide thumbs Also See for Handler 140:
Table of Contents

Advertisement

3-3. Duty Cycle And Overheating

200
140
100
80
60
40
20
10
1
Overheating

3-4. Volt-Ampere Curves

30
25
20
15
10
5
0
0
10
20
30
40
TM-258 267 Page 4
2
4
6
8
10
Duty Cycle %
20% duty cycle at 90 amps
2 Minutes Welding
0
Minutes
50
60
70
80
90
100
Amperage
40
60
80
20
8 Minutes Resting
15
OR
Reduce Duty Cycle
RANGE 5
RANGE 4
RANGE 3
RANGE 2
RANGE 1
110
120
130
140
150
Duty Cycle is percentage of 10
minutes that unit can weld at rated
load without overheating.
If unit overheats, thermostat(s)
opens, over temperature LED
lights, output stops, and cooling fan
runs. Wait fifteen minutes for unit to
cool, the therostat will automatically
reset. Reduce amperage or duty
cycle before welding.
NOTICE − Exceeding duty cycle
can damage unit or gun and void
warranty.
100
A or V
duty1 4/95 − 217 623-A
The volt-ampere curves show the
minimum and maximum voltage
and amperage output capabilities of
the welding power source. Curves
of other settings fall between the
curves shown.
ssb1.1 10/91 − 257 981-A
Handler 140

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

H100s2-10 gun

Table of Contents