INSTALLATION INSTRUCTIONS

1. All electrical work and materials must
comply with the National Electric
Code (NEC), the Occupational
Safety and Health Act (OSHA), and
all state and local codes.
2. Use copper conductors only.
3. DO NOT install the heater directly
above bathtub or sink. DO NOT
install in shower stall area. Cadet
recommends installing your heater
at least 2 feet (61 cm) away to
prevent contact with water.
4. Heater must be installed in a wall
can:
Model CM - wall can model CC or
CCSM
Wire Strippers
Drill and Drill Bits
Volt Meter
A multi-purpose tool or something to cut your existing drywall or gypsum board.
reset
button
built-in
thermostat
Vertical Mount
With Thermostat

TOOLS REQUIRED

Wire Connectors
Tape Measure
PARTS OF YOUR HEATER
heater element
fan and
motor
3
5. DO NOT install the heater in a floor,
in the ceiling, below a towel bar,
behind a door, or anywhere the air
discharge may be blocked in any
manner.
6. To reduce the risk of fire, do not
store or use gasoline or other flam-
mable vapors and liquids in the vi-
cinity of the heater.
7. Connect
grounding screw provided. Keep all
foreign objects out of heater.
8. CAUTION – High temperature, risk
of fire, keep electrical cords, drapery,
furnishings and other combustibles
at least 3 feet (0.9 m) from the front
of the heater and away from the side
and rear.
1½" Wood Screws
Hammer
reset button
grounding
lead
Straight and Phillips
Screwdrivers
½" Cable Clamp
Connector
Stud Finder
fan and
motor
Horizontal Mount