Installation Instructions - Cadet Com-Pak CBC132TW Owner's Manual

Bath heater
Table of Contents

Advertisement

Available languages

Available languages

READ ALL
INSTRUCTIONS
AND SAFETY
INFORMATION
IMPORTANT!
It is extremely
important you
verify the
electrical supply
wires are the same
voltage as the heater
(i.e. 120 volt heater to
120 volt power supply
and 240 volt heater
to 240 volt power
supply). If replacing
an existing heater,
check the labels of
the old heater and
replace using the
same voltage.
Hooking a 240 volt
heater to a 120 volt
power supply will
drastically reduce
the heater's
output. Hooking a 120
volt heater to a 240
volt power supply
will destroy the
heater. Connecting
your heater to an
incompatible power
supply will void the
warranty.
Warranty is void if
any material is
sprayed on the
element or blower.
2
PLACEMENT: Install The Com-Pak Bathroom Heater (Model CB) vertically. Heater is not approved for horizontal
or ceiling mount applications.
CONTROLS: A built-in thermostat and 60 minute timer. (Note: Do not use with a wall thermostat.)
How do I install for new construction?
Mount The Wall Can
STEP 1
The CB Series heater REQUIRES A MINIMUM distance
of 6 inches from adjacent surfaces and 4½ inches from
the floor. However, Cadet RECOMMENDS 12 inches
from all adjacent surfaces and 12 inches above the
floor for longer and cleaner performance. Heaters must
be spaced at least 3 feet apart.
Secure the wall can to the stud with 2 screws (See
Figures 1 & 2). As an option, the rubber shim provided
may be attached to side of wall can to square the wall
can to the stud.
Figure 1
Face of wall can must extend
½ or
5
allow for thickness of sheetrock.
Figure 2
Attach wall can to stud with
screws through holes provided
in wall can.
Connect Supply Wires
STEP 2
Route the supply wire from circuit breaker to heater.
Remove a knockout and attach the supply wire with
a strain relief connector leaving 10 inch wire lead for
later use. Connect supply ground wire to grounding
screw in wall can (See Figure 3). Proceed to PART TWO.
KNOCK-OUT
(TWIST TO REMOVE)
STRAIN RELIEF
CONNECTOR
Figure 3

Installation Instructions

Part One
/
inch from face of stud to
8
SUPPLY WIRE
GROUNDING
SCREW
Proceed to Part Two
How do I install in an existing wall?
Cut Hole In Wall
STEP 1
Cut a hole 8 inches wide by 10¼ inches high next to a
wall stud. This heater REQUIRES A MINIMUM distance
of 6 inches from adjacent wall surfaces and 4½ inches
from the floor. However, Cadet RECOMMENDS 12 inches
from all adjacent wall surfaces and 12 inches from the
floor (See Figure 4).
Figure 4
Model CB
Connect Supply Wires
STEP 2
Route supply wire from circuit breaker directly to
heater. Remove a knockout and attach the supply wire
with a strain relief connector, leaving 10 inch wire lead
for later use (See Figure 3). Connect supply ground wire
to grounding screw supplied in wall can.
Mount The Wall Can
STEP 3
Insert wall can into opening; keeping wall can flush with
wall surface. Secure can to wall stud with 2 screws
through holes provided in can.
Proceed to PART TWO