9 SIMOSTEP specifications
Specifications
Max. torque
Holding torque
Rotor inertia
Number of steps
Step angle
Systematic angle tolerance
1)
per step
Max. starting frequency
Nominal current/supply
line
Resistance/coil
Current rise time constant
Admissible dynamic
2)
shaft load
Weight (approx.)
Motor voltage
9-2
1FL3041 1FL3042 1FL3043 1FL3061 1FL3062
M
[Ncm]
200
m
M
[Ncm]
226
H
J
[kgcm²]
1.1
R
z
α [ °
∆α
[ ' ]
s
1)
f
[kHz]
Aom
I
[A]
1.75
w
6.5
R
[Ω]
w
τ [ms]
~7
axial [N]
~60
radial [N]
~100
G [kg]
2.05
U [V]
325
1)
Measured at 1000 steps/revolution
2)
Applied at half-way from shaft exit (motor flange).
Characteristics common to all type sizes
•
Test voltage acc. to VDE 0530
•
Degree of protection IP41 at front shaft exit
•
Degree of protection IP56 on terminal box
•
Insulation class F
•
Shaft runout and axial runout acc. to DIN 42955 N
•
Ambient temperature, operating -20°C to +40°C*
•
Transport and storage temperature -40°C to +70°C
*
Only if flange-mounting is correct
SIMOSTEP
400
600
1000
452
678
1130
2.2
3.3
500 / 1000 / 5000 / 10000
0.72 / 0.36 / 0.072 / 0.036
±6
5.3
2.0
2.25
5.8
6.5
~9
~10
~60
~60
~100
~110
~300
3.1
4.2
325
325
© Siemens AG 1998 All Rights Reserved
FM-STEPDRIVE/SIMOSTEP (FB)
02.05
1500
1695
10.5
16
4.3
4.1
4.75
1.8
1.9
~22
~22
~60
~60
~300
8.0
11
325
325