TABLE 1: RATINGS
COOLING CAPACITY
MODEL
80 / 67-95∞ F
BHP
MBH
SEER
024
24.4
13.0
030
30.0
13.0
036
35.5
13.0
042
42.0
13.0
048
47.0
13.0
1.
Certified in accordance with the Uniary Small Equipment certification program, which is based on ARI Standard 210/240.
2.
Rated in accordance with ARI Standard 270.
SEER =Seasonal Energy Efficiency Ratio - the total cooling output in BTU's during a normal annual usage period for cooling divided by the total electric
power input in watt-hours during the same period.
COP = Coefficient of Performance - the total heating capacity provided by the refrigeration system, including circulating fan heat but excluding supple-
mentary resistance (BGUís per hour) divided by the total electric input (watts) x 3.412.
TABLE 2: PHYSICAL DATA
INDOOR
CENTRIFUGAL BLOWER (Dia. x Wd. in.)
BLOWER
INDOOR
COIL
OUTDOOR
FAN
OUTDOOR
COIL
CHARGE
FILTER
COMPRESSOR
Unitary Products Group
BACK AND BOTTOM
RETURN AIR
AND SUPPLY AIR
DUCT OPENING
HIGH VOLTAGE
TERMINAL BLOCK
LOW VOLTAGE
TERMINAL BLOCK
LONG-LASTING
POWDER PAINT
FINISH
HIGH-EFFICIENCY
COMPRESSOR
RIGIDLY
MOUNTED
1
SOUND
1
2
RATING
HSPF
(dbels)
EER
11.3
7.6
79
11.3
7.6
77
11.3
7.6
77
11.3
7.6
83
11.3
7.6
82
MODELS
FAN MOTOR HP (ECM)
ROWS DEEP
FINS PER INCH
FACE AREA (Sq. Ft.)
PROPELLER DIA. (in.)
FAN MOTOR HP
NOM. CFM TOTAL
ROWS DEEP
FINS PER INCH
FACE AREA (Sq. Ft.)
REFRIGERANT 22 (lbs./oz.)
FACE AREA (Sq. Ft. / Qty. / Size)
Hermetic Type, Qty. = 1
HEAVY GAUGE
REMOVABLE
BASE RAILS
NET HEATING CAPACITY
@47∞ F
@17∞ F
MBH
COP
MBH
COP
21.8
3.40
11.0
2.00
28.2
3.40
16.5
2.20
32.0
3.30
18.9
2.20
42.0
3.40
23.0
2.20
45.0
3.30
25.8
2.20
024
10 X 8
1/2
2
15
4.38
22
1/4
1,800
1
20
11.7
5 / 5
Reciprocating
DIRECT DRIVE
CONDENSER
FAN MOTOR
HIGHLY EFFICIENT ENHANCED
COPPER TUBE/ALUMINUM FIN
INDOOR COIL
HIGHLY EFFICIENT
ENHANCED COPPER
TUBE/ALUMINUM FIN
OUTDOOR COIL
DECORATIVE
PROTECTIVE
COIL GUARD
ECM DIRECT DRIVE
BLOWER MOTOR WITH
SLIDE-OUT BLOWER ASSEMBLY
AVAILABLE ELECTRIC HEAT
NOMINAL CAPACITY KW
SINGLE PHASE
5.0, 7.5, 10.0
5.0, 7.5, 10.0, 15.0
5.0, 7.5, 10.0, 15.0
10.0, 15.0
10.0, 15.0, 20.0, 25.0
BHP
030
036
10 X 8
11 x 10
1/2
3/4
3
3
13
15
4.38
4.38
22
22
1/4
1/4
1,800
2,400
1
2
20
20
11.7
11.7
5 / 15
8 / 4
4.28 / 2 / 14 x 22
Scroll
Scroll
THREE PHASE
N / A
10.0, 15.0
10.0, 15.0
10.0, 15.0
10.0, 15.0, 20.0, 25.0
042
048
11 x 10
11 X 10
3/4
3/4
3
3
16
16
5.63
5.63
22
22
1/4
1/4
2,400
3,000
2
2
20
20
16.4
16.4
9 / 14
12 / 0
Scroll
Scroll
5