Single package heat pumps

Advertisement

DESCRIPTION

These packaged heat pumps are designed for outdoor
installation. Only utility and duct connections are required
at the point of installation.
Field-installed electric heater accessories are available to
provide electric heat, if required.

STANDARD FEATURES / BENEFITS

OPERATING EFFICIENCY
All units provide high operating efficiencies of 13 SEER, 3.3
COP or greater, and 7.6 HSPF. All efficiencies exceed leg-
islated minimum levels.
ON SITE FLEXIBILITY
All model sizes share a common, compact design cabinet
with a single footprint. The installer has the flexibility of set-
ting one curb or pad and placing the proper tonnage unit
after the internal load has been determined. Field convert-
ible duct connections, from side shot to down shot, allows
the installer greater flexibility and the need to carry less
inventory.
LOWER INSTALLATION COST
Installation time and costs are reduced by easy power and
control wiring connections. The small base dimension
means less space is required on the ground or roof. Plus,
the installer can fit this unit between the wheel wells of full
size pick-up truck. All models are under 500 pounds.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
CHAMPIONÆ PLUS
SINGLE PACKAGE
HEAT PUMPS
B1HP024 THRU 048
2 THRU 4 NOMINAL TONS
13 SEER
FACTORY MOUNTED TXV
All units are completely wired, charged with R-22 and
tested prior to shipment. Unique test stations, are used to
insure product quality. Refrigerant charge, and component
part numbers are verified via computers at manufacturing
point. Vital run test statistics, such as, system pressure,
motor currents, air velocity and temperature unit vibration
are monitored and recorded by the system to insure unit
performance.
Equal size, side supply and return duct connections allow
easy hook-up of ducts to match low crawl spaces without
transition pieces.
UTILITY CONNECTIONS MADE EASY
Electrical utility knockouts are provided through the bottom,
as well as the side of the unit. Utility connections can be
made quickly and with a minimum amount of field labor. A
field supplied and field installed electrical disconnect
switch must be installed.
CONVERTIBLE AIRFLOW DESIGN
The bottom duct openings are covered when they leave the
factory. They are ready for a side supply / side return appli-
cation. If a bottom supply / bottom return application is
desired, you simply remove the two panels from the bottom
of the unit and place them in the side supply / side return
duct openings. No panel cutting is required and no acces-
sory panel is necessary. Convertible airflow design allows
maximum field flexibility and minimum inventory.
036-21528-001-A-0303
®

Advertisement

Table of Contents
loading

Summary of Contents for York B1HP024 THRU 048

  • Page 1: Description

    FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE CHAMPIONÆ PLUS SINGLE PACKAGE HEAT PUMPS B1HP024 THRU 048 2 THRU 4 NOMINAL TONS 13 SEER FACTORY MOUNTED TXV All units are completely wired, charged with R-22 and tested prior to shipment.
  • Page 2 CONDENSATE PAN A non-corrosive, long-lasting, water-tight pan is posi- tioned below the evaporator coil to collect and drain all condensate; less collection of stagnate condensate will build-up. The condensate pan conforms to ASHRAE 62-89 standards (Ventilation for Acceptable Indoor Air Quality).
  • Page 3: Field-Installed Accessories

    036-21528-001-A-0303 PROTECTED COMPRESSOR The compressor is internally protected against high pressure and temperature. This is accomplished by the simultaneous operation of high pressure relief valve and a temperature sensor which protects the compres- sor, if undesirable operating conditions occur. EXCLUSIVE COIL DESIGN Grooved copper tubes and enhanced aluminum fin construction improves heat transfer for maximum effi- ciency and durability.
  • Page 4: Table Of Contents

    RECTANGLE TO ROUND ADAPTERS Kit includes one supply and one return air rectangle to round duct adapter. Adapters are preformed and designed to fit over current duct openings on the base unit. Transition is from 15" square to 14" round. ROOF CURBS NRCA approved curbs provide proper fit to base unit for rooftop installations.
  • Page 5: Unit Cut Away

    036-21528-001-A-0303 BACK AND BOTTOM RETURN AIR AND SUPPLY AIR DUCT OPENING HIGH VOLTAGE TERMINAL BLOCK LOW VOLTAGE TERMINAL BLOCK LONG-LASTING POWDER PAINT FINISH FIGURE 1 - UNIT CUT AWAY TABLE 1: RATINGS COOLING CAPACITY MODEL 80 / 67-95∞ F HSPF SEER 24.4 13.0...
  • Page 6: Cooling Capacities - 2 Ton (Bhp024)

    TABLE 3: COOLING CAPACITIES - 2 TON (BHP024) TEMPERATURE AIR ON OUTDOOR COIL NET CAP. MBH POWER INPUT kW 85 ∞ F NET CAP. MBH POWER INPUT kW 95 ∞ F NET CAP. MBH POWER INPUT kW 105 ∞ F NET CAP.
  • Page 7: Cooling Capacities - 2-1/2 Ton (Bhp030)

    036-21528-001-A-0303 TABLE 4: COOLING CAPACITIES - 2-1/2 TON (BHP030) TEMPERATURE AIR ON OUTDOOR COIL NET CAP. MBH POWER INPUT kW 85 ∞ F NET CAP. MBH POWER INPUT kW 95 ∞ F NET CAP. MBH POWER INPUT kW 105 ∞ F NET CAP.
  • Page 8: Cooling Capacities - 3 Ton (Bhp036)

    TABLE 5: COOLING CAPACITIES - 3 TON (BHP036) TEMPERATURE AIR ON OUTDOOR COIL NET CAP. MBH POWER INPUT kW 85 ∞ F NET CAP. MBH POWER INPUT kW 95 ∞ F NET CAP. MBH POWER INPUT kW 105 ∞ F NET CAP.
  • Page 9: Cooling Capacities - 3-1/2 Ton (Bhp042)

    036-21528-001-A-0303 TABLE 6: COOLING CAPACITIES - 3-1/2 TON (BHP042) TEMPERATURE AIR ON OUTDOOR COIL NET CAP. MBH POWER INPUT kW 85 ∞ F NET CAP. MBH POWER INPUT kW 95 ∞ F NET CAP. MBH POWER INPUT kW 105 ∞ F NET CAP.
  • Page 10: Cooling Capacities - 4 Ton (Bhp048)

    TABLE 7: COOLING CAPACITIES - 4 TON (BHP048) TEMPERATURE AIR ON OUTDOOR COIL NET CAP. MBH POWER INPUT kW 85 ∞ F NET CAP. MBH POWER INPUT kW 95 ∞ F NET CAP. MBH POWER INPUT kW 105 ∞ F NET CAP.
  • Page 11: Heating Capacities - 2 Ton (Bhp024)

    036-21528-001-A-0303 TABLE 8: HEATING CAPACITIES - 2 TON (BHP024) RETURN AIR ∞ F & KW 10.216 1.214 7.317 1.363 7.205 1.423 10.206 1.227 7.307 1.376 7.195 1.436 11.377 1.339 8.478 1000 1.488 8.366 1.548 These capacities are net capacities - the indoor motor heat has been added. These power inputs are total power inputs - the indoor motor watts have been added.
  • Page 12: Heating Capacities - 3 Ton (Bhp036)

    TABLE 10: HEATING CAPACITIES - 3 TON (BHP036) RETURN AIR ∞ F & KW 10.597 1.791 9.420 2.198 7.543 2.476 11.652 1.825 10.475 1200 2.232 8.598 2.510 12.282 1.779 11.105 1500 2.186 9.228 2.464 These capacities are net capacities - the indoor motor heat has been added. These power inputs are total power inputs - the indoor motor watts have been added.
  • Page 13: Heating Capacities - 4 Ton (Bhp048)

    036-21528-001-A-0303 TABLE 12: HEATING CAPACITIES - 4 TON (BHP048) RETURN AIR ∞ F & KW 13.911 2.342 11.264 1200 2.726 9.676 3.067 16.349 2.408 13.702 1600 2.792 12.114 3.133 17.629 2.502 14.982 2000 2.886 13.394 3.227 These capacities are net capacities - the indoor motor heat has been added. These power inputs are total power inputs - the indoor motor watts have been added.
  • Page 14: Side & Bot. Sup. Air Blower Perf. (208/230/460 Volts)

    TABLE 13: SIDE & BOTTOM SUPPLY AIR BLOWER PERFORMANCE (208/230/460 VOLT MODEL NO. B1HP024 Cooling TB2-A, Heating TB2-A, Electric Heat B1HP024 Cooling TB2-B, Heating TB2-B B1HP030 Cooling TB2-A, Heating TB2-A, Electric Heat B1HP030 Cooling TB2-B, Heating TB2-B B1HP036 Cooling TB2-A, Heating TB2-A B1HP036 Cooling TB2-B, Heating TB2-B, Electric Heat B1HP042...
  • Page 15: Field Wiring Diagram

    036-21528-001-A-0303 ** = Minimum wire size of 18 AWG wire should be used for all field installed 24 volt wire. PROGRAMMABLE THERMOSTAT ONLY * = Only required on units with supplemental electric heat. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.
  • Page 16: Electrical Data (Basic Unit)

    TABLE 15: ELECTRICAL DATA (BASIC UNIT) VOLTAGE COMPRESSOR LIMITATIONS MODEL POWER SUPPLY MIN. MAX. 208/230-1-60 208/230-1-60 15.0 208/230-3-60 10.0 460-3-60 208/230-1-60 17.2 208/230-3-60 11.4 460-3-60 208/230-1-60 20.0 208/230-3-60 13.9 460-3-60 208/230-1-60 23.4 208/230-3-60 13.0 460-3-60 Rated in accordance with ARI Standard 100, utilization range ìAî. Dual element, time delay type.
  • Page 17: Electrical Data (13 Seer Heat Pump / Electric Heat)

    036-21528-001-A-0303 TABLE 16: ELECTRICAL DATA (13 SEER HEAT PUMP / ELECTRIC HEAT) COMPRESSOR POWER SUPPLY 208/230-1-60 57.0 208/230-1-60 15.0 72.5 208/230-1-60 17.2 94.0 208/230-1-60 20.0 104.0 208/230-1-60 23.4 126.0 208/230-3-60 10.0 63.0 208/230-3-60 11.4 78.0 208/230-3-60 13.9 88.0 208/230-3-60 13.0 93.0 460-3-60 31.0...
  • Page 18: Application Data

    TABLE 17: APPLICATION DATA MODEL MINIMUM AIR FLOW (CFM) MAXIMUM AIR FLOW (CFM) MINIMUM OPERATING TEMPERATURE IN COOLING MODE (AMBIENT, ∞ F) MIMINIM MIXED AIR IN COOLING MODE (RETURN AIR, DB ∞ F/WB ∞ F) MINIMUM MIXED AIR IN HEATING MODE (RETURN AIR, ∞...
  • Page 19: Unit Dimensions

    036-21528-001-A-0303 FIGURE 5 - UNIT DIMENSIONS Unitary Products Group...
  • Page 20: Typical Applications

    036-21528-001-A-0303 FIGURE 6 - TYPICAL APPLICATIONS Unitary Products Group...
  • Page 21: Roof Curb Dimensions

    036-21528-001-A-0303 FIGURE 7 - ROOF CURB DIMENSIONS Unitary Products Group...
  • Page 22: Typical Wiring Diagram (208/230-1-60 Power Supply)

    036-21528-001-A-0303 FIGURE 8 - TYPICAL WIRING DIAGRAM (208/230-1-60 POWER SUPPLY) Unitary Products Group...
  • Page 23: Typical Wiring Diagram (230-3-60 Power Supply)

    036-21528-001-A-0303 FIGURE 9 - TYPICAL WIRING DIAGRAM (230-3-60 POWER SUPPLY) Unitary Products Group...
  • Page 24: Typical Wiring Diagram (460-3-60 Power Supply)

    036-21528-001-A-0303 FIGURE 10 - TYPICAL WIRING DIAGRAM (460-3-60 POWER SUPPLY) Unitary Products Group...
  • Page 25: Mechanical Specifications

    036-21528-001-A-0303 MECHANICAL SPECIFICATIONS GENERAL DESCRIPTION Units shall be factory-assembled, single packaged, Heat Pumps, designed for outdoor mounted installa- tion. Units shall have minimum SEER ratings of 13.0. They shall have built in, equal size, field convertible duct connections for down discharge supply/return or horizontal discharge supply/return.
  • Page 26 Shall have internal isolation and sound muffling to minimize vibration and noise, and be externally iso- lated on a dedicated, independent mounting. 2. Coils: Evaporator and condenser coils shall have alumi- num plate fins mechanically bonded to seamless internally-enhanced copper tubes with all joints brazed.
  • Page 27 036-21528-001-A-0303 Unitary Products Group...
  • Page 28 Subject to change without notice. Printed in U.S.A. Copyright © by Unitary Products Group 2003. All rights reserved. Unitary Products Group CD: 6-21528 5005 York Drive This product was manufactured in a plant whose quality system is certified/registered as being in conformity with ISO 9001. 036-21528-001-A-0303...