Dx Evaporator And Starter Options; Unit Enclosures Options; Fan Options; Sound Reduction Options - York YCAS0130 Installation, Operation & Maintenance Manual

Ycas air-cooled liquid chillers style g
Hide thumbs Also See for YCAS0130:
Table of Contents

Advertisement

Product Description
The following options provide added protection:
Black fi n condenser coils – Condenser coils con struct ed
using black epoxy coated Aluminum fi n stock for cor-
ro sion resistance comparable to copper fin coils in
typ i cal seashore locations.
Copper fi n condenser coils – Coils constructed with
corrosion resistant copper fi ns. Not recommended in
areas where units may be exposed to acid rain.
Phenolic coated condenser coils – Completed con-
dens er coil assemblies are covered with a cured Phe nol ic
coating. Probably the most suitable selection for sea-
shore locations where salt spray may come into con tact
with the fi ns, and other corrosive applications ex cept:
strong alkalis, oxidizers, and wet bromine, chlo rine, and
fl uorine in concentrations greater than 100 PPM.

DX EVAPORATOR AND STARTER OPTIONS

300 PSIG (21 bar) Waterside Design Working
Pressure – The DX evaporator waterside is designed
and con struct ed for 300 PSIG (21 bar) working pressure.
(Factory-mounted)
1-1/2" (38 mm) Insulation – Double thickness in su -
la tion provided for enhanced effi ciency.
Flange Accessory – Consists of raised face fl anges to
convert grooved water nozzles to fl anged evaporator
connections. Includes companion flanges for field-
mount ing. (See Page 33.)
Remote DX Evaporator – Includes the main con-
dens ing unit less the evaporator, re frig er ant and liquid
line de vic es. The insulated evaporator and fi eld acces-
sory kits per re frig er ant circuit are sup plied separately.
The condensing unit is shipped with a nitrogen holding
charge and the evaporator is shipped with a ni tro gen
hold ing charge.
Flow Switch Accessory – Johnson Controls model
F61MG-1C Vapor-proof SPDT, NEMA 4X switch, 150
PSIG (10 bar) DWP, -20°F to 250°F (-29°C to 121°C),
with 1" NPT (IPS) con nec tion for upright mounting in
horizontal pipe. A fl ow switch must be fi eld installed
with each unit. Optional 300 PSIG switch available.
Star-Delta Compressor Motor Starter – Provides ap-
proximately 65% reduced inrush current compared to
across-the-line start (Factory-mounted).
24

UNIT ENCLOSURES OPTIONS

Wire enclosure – Heavy gauge welded wire mesh
guards mounted on the exterior of the unit (Factory- or
fi eld-mounted).
Louvered panels and wired guards – Louvered pan-
els mounted over the exterior condenser coil faces, and
heavy gauge welded wire mesh guards mounted around
the bottom of the unit (Factory- or fi eld-mounted).
Louvered panels (condenser coils only) – Lou vered
panels are mounted over the exterior condenser coil faces
on the sides of the unit to visually screen and pro tect the
coils (Factory- or fi eld-mounted).
Louvered panels (full unit) enclosure – Louvered
panels over condenser coils and around the bottom of
the unit (Factory- or fi eld-mounted).

FAN OPTIONS

High static fans: Fans and motors suitable for High
External Static conditions to 100 Pa.

SOUND REDUCTION OPTIONS

Low speed fans – Reduced RPM fan motors and al ter -
na tive fan selection for low noise applications.
Compressor sound enclosures – Acoustically
treated metal compressor enclosures.

VIBRATION ISOLATION

Neoprene pad isolation – Recommended for normal
installations. (Field-mounted)
1" (25 mm) spring isolators – Level adjustable, spring
and cage type isolators for mounting under the unit base
rails (Field-mounted).
2" (51 mm) seismic spring isolators – Restrained
Spring-Flex Mountings incorporate welded steel hous-
ing with vertical and horizontal limit stops. Housings de-
signed to withstand a minimum 1.0 g accelerated force in
all directions to 2" (51 mm). Level ad just able, de fl ec tion
may vary slightly by application. (Field- mount ed).