Section 3. Scheduled Maintenance

The generator set alternator does not require regular or
scheduled service under normal operating conditions.
The prestart checklist lists the main areas of the
generator set that require attention.
If generator set operates under dusty or dirty conditions,
use DRY compressed air to blow dust out of the
generator. Do this with the generator set running and
direct the stream of air through the openings in the
generator end bracket.
Perform generator set engine service at the intervals
specified by the engine manufacturer in the engine
service literature.
Contact an authorized service
distributor/dealer to obtain service literature for specific
models.
Some generator sets may be equipped with an emission
certified engine. Emission certified engines are fitted
with carburetors that have no possible adjustments.
WARNING
Accidental starting.
Can cause severe injury or death.
Disconnect battery cables before working on
generator set (disconnect negative lead first and
reconnect it last).
Disabling generator set. Accidental starting can
cause severe injury or death. Turn generator set
master switch to OFF position, disconnect power to
battery charger, and remove battery cables (remove
negative lead first and reconnect it last) to disable
generator set before working on the generator set or
connected equipment. The generator set can be started
by an automatic transfer switch or remote start/stop
switch unless these precautions are followed.
TP-5631 7/96
WARNING
Hot coolant and steam.
Can cause severe injury or death.
Before removing pressure cap, stop generator set
and allow it to cool. Then loosen pressure cap to
relieve pressure.
Servicing exhaust system. Hot parts can cause
severe injury or death. Do not touch hot engine parts.
An engine becomes hot while running and exhaust
system components become extremely hot.
WARNING
Hazardous voltage.
Can cause severe injury or death.
Operate generator set only with all guards and
electrical enclosures in place.
Servicing generator set when operating. Exposed
moving parts can cause severe injury or death.
Keep hands, feet, hair, clothing, and test leads away
from belts and pulleys when generator set is running.
Replace guards, screens, and covers before operating
generator set.
Moving rotor.
Scheduled Maintenance 3-1