Port Mapping; Ethernet Led: Tx/Rx (Activity) - IBM Flex System EN4023 User Manual

10gb scalable switch
Table of Contents

Advertisement

2
Locating the information panel, LEDs, and external ports
Table 7
behavior.
TABLE 7
LED icon
!
Table 8
POST, all LEDs are lit briefly. Certain error conditions will illuminate the amber Fault LED; for
example, if temperatures exceed normal parameters. In such circumstances, power will shut off.
TABLE 8
System status LEDs functionality
Condition
Power LED (Green)
Pre POST
Off
POST start
First 1-3 seconds on,
then blinking during
diagnostics and
initialization
POST critical failure
Off
POST noncritical failure
On
POST complete OK
On
Extended POST start
On
Extended POST critical
Off
failure
Operational critical fault
Off
SCSE Location LED
On

Port mapping

The IBM Flex System EN4023 10Gb Scalable Switch provides 64 ports that can be configured as
Ethernet ports.
NOTES:
24
identifies the three system LEDs. After POST is successfully completed, this is normal LED
System status LEDs
LED name
The left-most LED is the Power LED.
The middle LED is the Location LED.
The right-most LED is the Fault LED.
identifies how the system status LEDs behave when certain conditions are met. During
Location LED (Blue)
Off
First 1-3 seconds on,
then off
Off
Off
Off
Off
Off
Off
On
Ports 1 through 42 provide up to 42 internal ports (available through Ports-On-Demand
activation) connected to 14 compute nodes at the midplane, auto-negotiating to 10-Gbps
Ethernet.
Ports 43 through 56 provide up to 14 external ports (available through Ports-On-Demand
activation), capable of supporting 1-Gbps Ethernet or 10-Gbps Ethernet through 10-Gbps SFP+
transceivers.
Ports 57 and 58 provide two Quad SFP (QSFP) ports (available through Ports-On-Demand
activation) that can support 40-Gbps Ethernet, or 4x10-Gbps Ethernet in breakout mode.
LED description
When lit, it appears solid green.
When lit, it appears solid blue.
When lit, it appears solid amber.
Fault LED (Amber)
Comments
Off
Power off
First 1-3 seconds on,
Lamp test progress indication
then off
On
Switch nonfunctional; replacement
required
Off
Switch operational in degraded mode
Off
Fully operational
Off
Switch operational in degraded mode
On
Switch nonfunctional; replacement
required
On
Switch nonfunctional; replacement
required.
Off
Location LED operation from CMM
IBM Flex System EN4023 10Gb Scalable Switch User's Guide