Commissioning
5.5 Options of the VLplus heavy-duty bearing system
At an ambient temperature of -10 °C, the actual lubrication time is twice that for the set
temperature.
At an ambient temperature of +40 °C, the actual lubrication time drops to approximately half
that for the set temperature.
Figure 5-7
Procedure
1. Set the lubrication time with a 3 mm Allen key.
2. Note the date of commissioning and the lubrication time on the lubricator.
The times in months listed in the table are guide values.
Table 5- 2
Size
Months
5.5.2

Dry-well version with oil sensor

Please refer to the separate operating instructions for the oil level sensor.
Functional restriction of the sensor
Note the following:
• The sensor must be free of any dirt and residues.
• Do not damage the cables or the insulation.
• Lay the supply line with strain relief.
• Avoid strong bending loads, buckling and point mechanical loads.
54
Lubrication time controller
Timing in months on the lubrication time controller
89
12
CAUTION
109
129
12
12
Operating Instructions, 07/2020, A5E50009094A/RS-AL
149
169
12
11
BA 2030 (2KJ4)