Adjusting Reversing Sensor(S) - Chamberlain Elite CSW-200-UL Owner's Manual

Vehicular swing gate operator
Hide thumbs Also See for Elite CSW-200-UL:
Table of Contents

Advertisement

Adjust the
"Reverse
Sensor" on the OmniControl™ board. Alarm Sensor does not need to be adjusted except where noted below.
Sensor is too sensitive
Sensor is not sensitive enough
3
NOTE: If the power supply to
the operator is less than 99
volts, adjust the ALARM
SENSOR by turning the alarm
adjustment counter-clockwise
enough to actuate the alarm
when obstructed but not
sensitive enough for false
triggering to occur.
D C 2 0 0 0 ™ R e v e r s e S e n s o r
The DC2000™ has a separate reverse sensor that will need to be adjusted. The 110 Vac
operator power needs to be turned off and the DC2000™ should have the
LED
ON
to make the adjustment.
A D J U S T I N G R E V E R S I N G S E N S O R ( S )
The level of reverse sensitivity depends on the weight of the gate
and the condition of installation.
= if the gate stops in midcycle or reverses by itself.
1
3
1
3
= if the gate hits an object and does not stop or reverse.
Maximum
Sensitivity
CENTER
Minimum
Sensitivity
W4
G B
"Charge
OK"
31
SAFETY
EXIT
A
SYSTEM ON
MS LINK
SENSORS
1
3
1
FIRE
DEPT.
EXIT
LOOP
DC-BACKUP
TIMER
POWER
60
3
OVERLOAD
1
3
OFF
ON
MADE IN USA
3
OPEN LEFT
OPEN RIGHT
STRIKE
RADIO
GATE
OPEN
RECEIVER
LOCKED
SAFETY
CENTER
RESET
LOOP
LOOP
MOTOR
Maximum
Sensitivity
Minimum
Sensitivity

Advertisement

Table of Contents
loading