Non-Contact Sensors (24 VDC Photo Electric Sensors)
NOTE: Property owners are
obligated to test photo
sensors monthly.
NOTE: If the photo beam gets blocked
while the gate is closing, it will stop and
reopen. The gate will remain open until
the obstruction is cleared.
E N T R A P M E N T P R O T E C T I O N D E V I C E S
Entrapment Non-Contact Sensor
Safety Non-Contact Sensor
To prevent SERIOUS INJURY or DEATH from a moving gate:
• Locate entrapment protection devices to protect in BOTH the
open and close gate cycles.
• Locate entrapment protection devices to protect between
moving gate and RIGID objects, such as posts or walls.
UP
11 13
®
+24V
Brown
SENSING
COMMON
Wires
EDGE
INPUT
INFRARED
BLACK or BROWN
INFRARED
WHITE or BLUE
Blue Wires
Brown
Wires
Blue Wires
It is best to use Failsafe Photo Electric Sensors for this
Safety Option.
Failsafe Photo Sensors: If a failsafe photo sensor is not
working or loses power or photo beam is blocked, then
the photo beam will stop ALL gate operation.
25
25
WARNING
CENTER
SAFETY
EXIT
W4
G B
A
SYSTEM ON
TIMER
MS LINK
SENSORS
OFF
1
3
1
3
OPEN LEFT
FIRE
STRIKE
RADIO
DEPT.
OPEN
RECEIVER
EXIT
SAFETY
CENTER
LOOP
LOOP
LOOP
®
G
B
A
1
2
3
4
5
6
7
8
9
10
Part #
CPSN4
®
G
B
A
7
1
2
3
4
5
6
11 13
®
3 4
+24V
SENSING
COMMON
EDGE
INPUT
INFRARED
BLACK or BROWN
INFRARED
WHITE or BLUE
Contact your local dealer for more
information about photo electric sensors.
DC-BACKUP
POWER
60
3
OVERLOAD
1
3
ON
MADE IN USA
OPEN RIGHT
GATE
LOCKED
RESET
MOTOR
11
12
13
+
8
9
10
11
12
13
+