Electrical Requirements:
230 volts AC, 50 Hz
•
2 wire (plus ground), single phase
•
40 amp required
•
THE WARRANTY IS VOID IF THE SMOKER IS CONNECTED TO ANY VOLTAGE OTHER
THAN SPECIFIED ABOVE AND ON THE SMOKER DATA PLATE. THE CHASSIS MUST BE
GROUNDED TO PREVENT POSSIBLE SHOCK HAZARD.
Remove all packing material before connecting the electrical supply to the smoker.
The smoker is not equipped with a power cord from the factory.
Power supply connections should be made with flexible conduit. Use a No. 12 AWG wire suitable for at
least 90° C.
The power is to be left OFF throughout the installation.
Electrical service is provided to the smoker at the main terminal block located behind the access panel in
the lower rear left corner of the smoker.
Verify correct voltage at the main terminal block and replace the access panel.
The restraining device must be installed.
INSTALLATION
ELECTRICAL INSTRUCTIONS
9 of 24
WARNING:
This appliance, when installed, must be electrically
grounded in accordance with local codes
Copyright 2019 by Southern Pride Distributing, LLC Revision 1
.