1. Ports
The mLAN MIDI ports 1, 4 and 5 are used to communicate
via MIDI with the 01X. The mLAN MIDI ports 2 and 3 are
connected directly to the MIDI-A and MIDI-B terminals of the
01X and do not communicate via MIDI with the 01X.
2. Function Outline
MIDI is used with the 01X for the following purposes/pro-
grams.
• Studio Manager
• Controlling the DAW software
• Controlling the Multi Part Editor
• Recalling preset Library Scenes
(via program change messages)
The port-related functions are assigned to specific ports as
indicated in the chart below.
mLAN MIDI Port
mLAN-MIDI-1
Remote control (Mode can be selected.)
mLAN-MIDI-2
Direct connection to MIDI-A terminal
mLAN-MIDI-3
Direct connection to MIDI-B terminal
mLAN-MIDI-4
Studio Manager
Remote control (Mode is fixed to "GENERAL." This
is used for control of the Multi Part Editor, or for
mLAN-MIDI-5
recalling Library Scenes by program change mes-
sages. Selection between the two is done from the
Utility menu.)
3. Data Format
The MIDI format to be used for each function is shown
below. The explanations here pertain only to changing 01X
Scenes via the mLAN MIDI Port 5.
Function
GENERAL
LOGIC
CUBASE
Remote Control
SONAR
DIGITAL
PERFORMER
Studio Manager
Recalling of Library Scenes
3.1 Channel Messages
Command
rx/tx
Cn PROGRAM CHANGE
rx/tx

MIDI Data Format

Function
Format
01X Remote General format
Special format
Special format
Special format
Special format
Special format
Program Change messages
function
For switching the Library Scene
memory
3.2 System Common Messages
No relevant messages.
3.3 System Real-time Messages
Command
rx/tx
FE ACTIVE SENSING
rx
FF RESET
rx
3.4 System Exclusive Messages
No relevant messages.
4. Format Details
4.1 Program Change
These messages are effective only when the SHIFT +
REMOTE function is set to "NO ASSIGN" (SCENE CTL).
< Receiving >
Data is received when PROGRAM CHANGE RX is on and
the receive channel settings match. However, when OMNI
is set to on, reception is enabled regardless of the channel
settings. Upon reception, Library Scenes are recalled
according to the settings of the Program Change Assign
Table.
< Transmitting >
When PROGRAM CHANGE TX is on, recalling a Library
Scene transmits data via the set transmit channel, accord-
ing to the settings of the Program Change Assign Table.
STATUS
1100nnnn
Cn
DATA
0nnnnnnn
nn
4.2 Active Sensing (FE)
< Receiving >
If no Active Sensing messages are received within 400 ms,
MIDI communications are initialized, such as clearing the
Running Status.
STATUS
11111110
FE
4.3 System Reset (FF)
< Receiving >
Upon reception, this initializes MIDI communications, such
as clearing the Running Status.
STATUS
11111111
FF
MIDI Data Format
function
For checking MIDI cable connec-
tion
Clear the running status
Program change
Program number (0-127)
Active sensing
System reset
01X Owner's Manual