MIDI DATA FORMAT

1. DATA FORMAT
1.1 CHANNEL MESSAGE
Command
rx/tx
8n NOTE OFF
rx
9n NOTE ON
rx
Bn CONTROL CHANGE
rx/tx
Cn PROGRAM CHANGE
rx/tx
1.2 SYSTEM COMMON MESSAGE
Command
rx/tx
F1 MIDI TIME CODE QUARTER
rx
FRAME
F2 SONG POSITION POINTER
rx
1.3 SYSTEM REAL T IME MESSAGE
Command
rx/tx
F8 TIMING CLOCK
rx
FA START
rx
FB CONTINUE
rx
FC STOP
rx
FE ACTIVE SENSING
rx
FF RESET
rx
1.4 EXCLUSIVE MESSAGE
1.4.1 Real Time System Exclusive
Command
rx/tx
F0 7F dd 06 ... F7 MMC
tx
COMMAND
F0 7F dd 07 ... F7 MMC RESPONSE rx
F0 7F dd 01 ... F7 MIDI TIME CODE
rx
1.4.2 System Exclusive Message
1.4.2.1 Bulk Dump
Command
rx/tx
F0 43 0n 7E ... F7 BULK DUMP
rx/tx
DATA
F0 43 2n 7E ... F7 BULK DUMP
rx/tx
REQUEST
The following data types of bulk dump are used on the DM1000.
Data name
tx/rx
'm'
tx/rx
'S'
tx/rx
'a'
tx/rx
'R'
tx/rx
'O'
tx/rx
'H'
tx/rx
'G'
tx/rx
'Y'
tx/rx
'Q'
tx/rx
'E'
tx/rx
'J'
tx/rx
'K'
tx/rx
'P'
tx/rx
'C'
tx/rx
'L'
tx/rx
'V'
tx/rx
'U'
tx/rx
'N'
tx/rx
1.4.2.2 PARAMTER CHANGE
function
Control the internal effects
Control the internal effects
Control parameters
Switch scene memories
The following data types of parameter change are used by the DM1000.
function
MTC
Used when TIME REFERENCE is
MIDI CLOCK.
function
MIDI clock
Start automix (from the beginning)
Start automix (from the middle)
Stop automix
Check MIDI cable connections
Clear running status
function
* 'tx' indicates that the data can be transmitted from the DM1000, and
MMC command
MMC response
2. Format Details
MTC full message
2.1 NOTE OFF
Reception
If [OTHER ECHO] is ON, these message are echoed from MIDI OUT.
function
If the [Rx CH] matches, these messages are received and used to control effects.
BULK DUMP DATA
STATUS
BULK DUMP REQUEST
DATA
function
2.2 NOTE ON
Scene Memory & Request
(compressed data)
Reception
Setup Memory & Request
If [OTHER ECHO] is ON, these messages are echoed from MIDI OUT.
Automix data & Request
If the [Rx CH] matches, these messages are received and used to control effects.
(compressed data)
STATUS
Input patch library & Request
DATA
Output patch library & Request
Channel library & Request
Gate library & Request
Compressor library & Request
2.3 CONTROL CHANGE
Equalizer library & Request
Reception
Effect library & Request
If [Control Change ECHO] is ON, these messages are echoed from MIDI OUT.
Bus to Stereo library & Request
If [TABLE] is selected, these message are received if [Control Change Rx] is ON,
Surround Monitor library & Request
and will control parameters according to the [Control assign table] settings.
Program change table & Request
The parameters that can be set are defined in the Control Change Assign Pa-
Control change table & Request
rameter List.
User define layer & Request
If [NRPN] is selected, these messages are received if [Control Change Rx] is ON
User define key & Request
and the [Rx CH] matches, and will control the parameter that is specified by the
User assignable layer & Request
four messages NRPN control number (62h, 63h) and Data Entry control num-
Plug-in Effect Card Data & Request
ber (06h, 26h). Parameter settings are defined in the Control Change Assign Pa-
rameter List.
Command
rx/tx
F0 43 1n 3E 0C ... F7 RARAMETER
rx/tx
CHANGE
F0 43 3n 3E 0C ... F7 PARAMETER
rx/tx
REQUEST
F0 43 1n 3E 7F ... F7 PARAMETER
rx/tx
CHANGE
F0 43 3n 3E 7F ... F7 PARAMETER
rx/tx
REQUEST
Type (HEX)
tx/rx
1 (01)
tx/rx
2 (02)
tx/rx
3 (03)
tx/rx
4 (04)
tx/rx
15 (0F)
tx/rx
16 (10)
tx/rx
17 (11)
rx
18 (12)
rx
19 (13)
tx/rx
20 (14)
tx/rx
32 (20)
rx
33 (21)
tx/rx
34 (22)
tx/rx
35 (23)
tx/rx
80 (50)
tx/rx
84 (54)
tx/rx
126 (7E)
tx/rx
127 (7F)
tx
'rx' indicates that the data can be received by the DM1000.
Note off message
1000nnnn 8n
Note number
0nnnnnnn nn
Velocity(ignored)
0vvvvvvv vv
Note on message
1001nnnn 9n
0nnnnnnn nn
Note number
Velocity(1-127:on, 0:off)
0vvvvvvv vv
DM1000/MB1000/SP1000
function
DM1000-specific parameter change
DM1000-specific parameter change
General purpose digital mixer
parameter change
General purpose digital mixer
parameter request
function
Edit buffer
Patch data
Setup data
Backup data
Cascade data
Function (recall, store, title, clear)
Function (pair, copy)
Function (effect)
Sort table
Function (attribute, link)
Key remote
Remote meter
Remote time counter
Automix status
Function response (recall, store,
title, clear)
Function response (attribute, link)
System Attribute
Active sense
(8n)