Specifications; Channel Menu; Operation Sub-Menu - Honeywell SC Series Installation Instructions Manual

Signal conditioning self-calibrating digital indicators
Table of Contents

Advertisement

SC 2000, SC2001, SC3004

12.5 Specifications

TRANSDUCER INPUT
Transducer type
Excitation voltage
1
Excitation overcurrent
protection
Transducer full-scale
output
Amplifier gain selection
Calibration type
Differential Input Volt-
age
A/D Converter
Low-pass filter
Resolution and frequen-
cy response
INSTRUMENT-ONLY ACCURACY
(Sense wires used; frequency response setting <16 Hz; Linearity, repeatability,
and hysteresis)
Known-load calibration
AUXILLARY INPUTS
Quantity
Type
Response time
Field-selectable func-
tions
ANALOG OUTPUTS
Output voltage range
Output current range
(optional current output
channels)
Source
Isolation
Resolution
Frequency response
Total excitation current of all channels must not exceed 120 mA
1
for Models SC2000 or SC2001 and 310 mA for Model SC3004.
amplified with voltage or current
output, (field selectable)
±15 Vdc @ 40 mA max.
+28 Vdc @ 75 mA max.
+12 Vdc @ 40 mA max.
(field selectable)
yes
±1, ±5, ±10 Vdc
4 mA to 20 mA (field selectable)
automatic
shunt, or 2-, 3- or 5-point known load
±55 mV (max.)
24-bit Sigma-Delta
digital, 24-tap FIR
see "FREQ. RESPONSE Menu Item" on
page 58
±0.01% FS
2
momentary contact closure
< 5 ms
tare on, tare off, peak/valley clear,
peak/valley hold, track hold
5, ±5, 10 or ±10 Vdc (field select-
able)
4 mA to 20 mA
any channel's track, peak, or valley
value
500 V
13 bits
same as input when driven by the
same channel's tracking data

12.6 Channel Menu

Each High-Level Input channel is configured and calibrated via
its channel menu. Detailed instructions on operating the instru-
ment in the SETUP Menu mode can be found in "SETUP Menu
mode" on page 7. A diagram of all menus is located in "Setup
Menu Reference" on page 77.

12.6.1 OPERATION Sub-Menu

This menu controls the operation of this channel when the instru-
ment is in the RUN mode.
AUTO-ZERO Menu Item
This enables or disables the channel's automatic zeroing func-
tion. The auto-zero function can remove the effect of slight tem-
perature shifts in the transducer's output. The two options for this
menu item are "ON" and "OFF".
When enabled, the channel will reset its tracking value to zero
when the tracking value has never been more positive than +10
or more negative than -10 display counts for any 10 second
period.
For example, assume that the DISPLAY.DECPT menu item is set to
000.00 (two decimal points). If the tracking value never leaves
the range of -000.10 to +000.10 for any 10 second period, then
tracking value will reset to 000.00 automatically.
NOTICE
To compensate for the transducer's initial warm-up shift, the
auto-zero function operates every 2 seconds during the first
60 seconds of RUN mode operation.
008-0608-00
Rev. G,
Honeywell Sensing and Control
57