11 TROUBLESHOOTING

During Normal Operation, Thermo Switch Activated

Table 11-13 During Normal Operation, Thermo Switch Activated

Problem
During Normal Opera-
tion, Thermo Switch Ac-
tivated
200
Cause
Coolant temperature
raised
Mitsubishi Diesel Engine S16R & S16R2 OPERATION & MAINTENANCE MANUAL
Remedies
Restart the engine in the following order:
Operate the engine at low idle
1
speed to cool down
immediately.
Stop the engine.
2
Check the coolant level.
3
Check the ambient
4
temperature.
Bleed air from the cooling
5
system.
Check the radiator, fan, and
6
fan belt.
Check the coolant
7
temperature.
If no fault has been found,
8
restart the engine.
• If any fault is found, contact
your SME dealer
LIST" (→ Page
8).
Reference
Page
-
"CONTACT
Pub. No. K29001-00320 Revision: 1