8 INSPECTION AND MAINTENANCE
■ Coolant - Refill
Close the coolant drain cock of (1) on
1
the engine securely.
(1)
Fig. 8-102 Coolant Drain Cock on Engine Body
Close the coolant drain cock (2) on
2
the water pump securely.
(2)
Fig. 8-103 Coolant Drain Cock on Water Pump
170
Open the coolant filler cap and
3
slowly refill the specified quantity of
coolant.
• For the specified quantity of coolant,
refer to
(→ Page
• For mixing coolant, refer to
Mix" (→ Page
• Refill slowly to prevent air included in
the coolant.
Wait approx. 30 minutes untill the
4
coolant to circulate all parts of the
coolant system, then check the
coolant quantity again.
Check the heat exchanger and other
5
part in the coolant system for
coolant leaks.
• If a leak is found, contact your SME
dealer
arrange the repair.
Close the coolant filler cap properly.
6
Bleed air from the fuel system
7
"Cooling System - Bleed Air" (→ Page
171).