Operation

Operation
Operation
Lifting the
the System
System
Lifting
Lifting
the
System
• Lift the system with a lift apparatus rated
appropriately for the weight of the system
(see
Technical Specifications, page
• Do not lift the system by the handle on the EQm pot.
• Lift the system using the lift eyes shown on the
appropriate illustration.
EQs, EQs
EQs Elite,
Elite, and
and EQs2
EQs2 Elite
EQs,
EQs,
EQs
Elite,
and
EQs2
EQm
EQm Models:
EQm
Models:
Models:
3A3489A
66).
Elite Models:
Models:
Elite
Models:
Blast Hose
Hose Selection
Selection
Blast
Blast
Hose
Selection
Make sure to use the correct type of blast control. An
electric or pneumatic blast control switch can be used
with hose lengths less than 150 ft (45 m). Blasting
with 150 ft (45 m) or more of blast hose requires the
use of an electric blast control switch.
Blasting on
on Higher
Higher Surfaces
Blasting
Blasting
on
Higher
NOTICE
NOTICE
NOTICE
When blasting on a surface higher than the
equipment, make sure that there is a length of
blast hose on the ground equal to 10-20% of the
height. The hose on the ground prevents unspent
abrasive in the hose from backing up into the
internal plumbing of the panel, which can cause
damage to the main air regulator when the blast
switch is disengaged.
For example: When blasting 50 feet (15 m) straight
up, use at least 10 feet (3 m) of blast hose on the
ground before the blast hose goes up to the blasting
height.