Installation
This section contains the installation procedures and details for the XTP T HWP 101 4K.
Topics in this section include the following:
•
•
•
•
•
•
Installation Overview
The XTP T HWP 101 4K can be installed into the provided mud ring or a UL Listed metal
electrical junction box.
NOTE: If a junction box is required, it must be metal.
1.
2.
Installation Overview
Metal Junction Box or Mud Ring Installation
Rear Panel Connectors
Mounting the Device
Front Panel Connectors
Connection Details
Prepare the mounting surface.
CAUTION: Risk of personal injury. Failure to check the items listed below may
result in personal injury.
ATTENTION : Risque de blessure. La non-vérification des éléments listés
ci-dessous peut provoquer des blessures.
ATTENTION:
•
Failure to check the items listed below may result in property damage.
•
La non-vérification des éléments listés ci-dessous peut provoquer des
dommages matériels.
Ensure there are no utility cables or pipes at the intended location that might be
•
damaged or cause injury when installing the device.
Check that the installation meets building, electrical, and safety codes.
•
Ensure there is sufficient space behind the device.
•
Choose a location that will allow cable runs without interference.
•
NOTES:
•
Cables may need to be installed in the wall or conduits before installation.
•
The mud ring does not require attachment to wall studs.
•
For metal junction boxes, refer to the manufacturer for more installation
requirements.
Cut a hole in the mounting surface (see
page).
Mounting Surface Preparation
XTP T HWP 101 4K Wallplate Transmitter • Installation
on the next
4