Sony HDC5500 Operating Instructions Manual page 52

Hide thumbs Also See for HDC5500:
Table of Contents

Advertisement

MAINTENANCE
Page name
Item
Page No.
<LENS1>
F NO. DISP
M06
AF DISPLAY
ALAC
F DROP COMP
MAX GAIN
DROP POINT
ROUNDNESS
STORE LENS FILE
ARIA
<LENS2>
REMOTE CONTROL
M07
CONTROL MODE
FOLLOW FOCUS
OFFSET ADJUST
SENS
OFFSET CANCEL
GAIN
<MIC GAIN>
MIC1
M08
MIC2
Settings
CONTROL, RETURN
ON, OFF
AUTO, OFF
OFF, ON, (OFF)
0.0 to 24 dB
0 to 99, 50
0.0 to 12 dB
Execute using ENTER.
AUTO, OFF
OFF, ON, (OFF)
ZOOM&FOCUS, FOCUS,
FOLLOW FOCUS
1, 2, 3, 4, 5
1, 2, 3, 4, 5
20, 30, 40, 50, 60 dB
20, 30, 40, 50, 60 dB
52
Description
Selects the iris indication on the panel when AUTO
IRIS is off:
CONTROL: Displays the value from the camera.
RETURN: Displays the value returned from the lens.
(When AUTO IRIS is on, the value returned from the
lens is always displayed.)
With AUTO selected, the status is displayed at the
right.
(ACTIVE): Compensation is in progress.
(WAIT): Waiting for completion of lens initialization.
(STOP): Compensation is turned off for a non-
applicable lens.
Turns F drop compensation on/off.
During compensation, the compensation gain is
displayed on the right.
(OFF): For when a serial lens is not attached.
Maximum compensation value
Compensation start point
Roundness of the compensation curve.
Saves settings to a lens file.
With AUTO selected, the status is displayed at the
right.
(ACTIVE): Compensation is in progress.
(WAIT): Waiting for completion of lens initialization.
(STOP): Compensation is turned off for a non-
applicable lens.
Lens remote control from MSU/RCP on/off setting.
Same function as the Active button on the Zoom/
Focus Control screen of the MSU/RCP.
(OFF): When lens is not supported
ZOOM&FOCUS: Control ZOOM and FOCUS from an
MSU/RCP (control by lens demand is not
supported)
FOCUS: Control FOCUS from an MSU/RCP. ZOOM is
controlled by lens demand.
FOLLOW FOCUS: FOCUS is controlled by lens
demand, but can be adjusted (offset fine
adjustment) from an MSU/RCP. ZOOM is controlled
by lens demand.
Note
Settings other than FOLLOW FOCUS cannot be
modified when the offset is not 0 and REMOTE
CONTROL is OFF. To change settings, set REMOTE
CONTROL to ON.
Sets the sensitivity of superimposing the offset of the
MSU.
Sets the sensitivity of canceling the offset on the
demand side.
Can be modified only in standalone operation.

Advertisement