3 Safety-Related Functions
3.5 Safely-reduced speed (SG)
3.5.1

Selecting/de-selecting the safely-reduced speed

Selecting SG
The following SGEs are used to select SG:
Table 3-22
Selecting speed limit
The maximum permissible speed of an axis/spindle in the setting-up mode is
values
defined for individual machine types in the C Standards (product standards).
The machine manufacturer is responsible for ensuring that the correct speed
limit value is selected as a function of operating mode and application.
The required speed limit value is selected as follows by combining the following
SGEs:
Table 3-23
Changing the speed
The changeover from a lower to a higher speed limit value takes effect without
limit values
delay.
When changing-over from a higher to a lower limit value, then a delay time is
started that is parameterized using the machine data (refer to Fig. 3-6, "Timing
when changing over from a higher to a lower speed limit value).
3-94
SINUMERIK 840D/SIMODRIVE 611 digital SINUMERIK Safety Integrated (FBSI) - Edition 11.03
Selecting/de-selecting SG
SGE
SBH/SG
SBH
de-selection
de-selection
= 1
x
= 0
= 0
= 0
= 1
Note: x
Any signal state
Note
The current status of the function is displayed using the SGA "SBH/SG
active" and SGA "SBH active".
Before the SG function is activated, it must be ensured that the speed of the
axis/spindle is lower than the selected speed limit value. If it is higher, an
alarm is generated that causes the drive to be shut down.
The SGEs and SGAs are described in Chapter 3.9, "Safety-relevant
input/output signals (SGE/SGA)".
Selecting speed limit values for the SGs
SGE
SG selection
SG selection
Bit 1
Bit 0
= 0
= 0
= 0
= 1
= 1
= 0
= 1
= 1
Note:
1) For SINUMERIK 840D system with SW 4.2 and higher, the SG limit value SG2 and
SG4 can be set in finer steps using the SG override (refer to Chapter 3.5.6, "Override
for safely-reduced speed").
The active SG stage is displayed via SGA "SGA active bit 0" and "SGA active bit 1".
Meaning
SBH and SG are de-selected
SBH is selected
(refer to Chapter 3, "Safe operating stop (SBH)")
SG is selected
Meaning
Speed limit value for SG1 active
Speed limit value for SG2 active
Speed limit value for SG3 active
Speed limit value for SG4 active