3.5
Load hardware configuration into the PLC
Requirement
● The hardware configuration is compiled.
● A communication connection exists between the PG/PC (TIA Portal) and the NCU.
Note
Loading configurations to simulated environments
If you want to use the configuration in a simulated environment, you must activate the
simulation capability in the project properties before you load the configuration into the
simulated environment or compile the hardware/software.
Note
General reset before loading into a PLC with Safety Integrated plus (F-PLC)
If the actual hardware has been operated in Safety Integrated plus (F-PLC) mode and you now
want to load a configured hardware configuration with changed Safety Integrated mode, you
must perform a general reset of the PLC prior to the loading.
SINUMERIK STEP 7 Toolbox V15.1
Configuration Manual, 12/2018, A5E46279635B AA
3.5 Load hardware configuration into the PLC
Configuring the NCU
39