Siemens SINUMERIK 840D sl Configuration Manual page 114

Sinumerik step 7 toolbox v15.1
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Configuring networks
5.5 Configuring PROFINET IO with IRT
Assignment of the IO modules to the NCK machine data
MD10500 $MN_DPIO_LOGIC_ADDRESS_IN[0]=1016
MD10500 $MN_DPIO_LOGIC_ADDRESS_IN[1]=1018
MD10500 $MN_DPIO_LOGIC_ADDRESS_IN[2]=1020
MD10501 $MN_DPIO_RANGE_LENGTH_IN[0]=1
MD10501 $MN_DPIO_RANGE_LENGTH_IN[1]=1
MD10501 $MN_DPIO_RANGE_LENGTH_IN[2]=4
MD10510 $MN_DPIO_LOGIC_ADDRESS_OUT[0]=1018
MD10510 $MN_DPIO_LOGIC_ADDRESS_OUT[1]=1020
MD10511 $MN_DPIO_RANGE_LENGTH_OUT[0]=1
MD10511 $MN_DPIO_RANGE_LENGTH_OUT[1]=4
Further information
● General information concerning this machine data is available in Chapter A4 of the
SINUMERIK 840D sl Supplementary Functions Manual: Digital and analog NCK I/Os for
SINUMERIK 840D sl.
● Specific information on the individual machine data can be found in the online help of
SINUMERIK Operate.
114
SINUMERIK STEP 7 Toolbox V15.1
Configuration Manual, 12/2018, A5E46279635B AA