XCITING 400i
3. Engine > Engine Removal
Loosen the water pump hose clamp with a #2 Phillips screwdriver. Slide
up the clamp and free the coolant hose from the water pump. Allow any
remaining coolant to drain into a suitable container.
Loosen the thermostat hose clamp with a #2 Phillips screwdriver. Slide
up the clamp and free the coolant hose from the thermostat. Allow any
remaining coolant to drain into a suitable container.
Squeeze the air bleed hose clamp with needle nose pliers and slide
back the clamp. Free the air bleed hose from the thermostat.
4‐8