Characteristics
Indication accuracy
Hysteresis
Proportional band (P)
Integral time (I)
Derivative time (D)
Control period
Manual reset value
Alarm setting range
Sampling period
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Weight
Degree of protection
Memory protection
EMC
Approved standards
Compliant standards
Note: The indication of K thermocouples in the − 200 to 1300 ° C range, and T and N thermocouples at a temperature of − 100 ° C or less, and U and
L thermocouples at any temperature is ± 2 ° C ± 1 digit maximum. The indication of B thermocouples at a temperature of 400 ° C or less is un-
restricted.
The indication of R and S thermocouples at a temperature of 200 ° C or less is ± 3 ° C ± 1 digit maximum.
Thermocouple:
( ± 0.5% of indicated value or ± 1 ° C, whichever greater) ± 1 digit max. (see note)
Platinum resistance thermometer:
( ± 0.5% of indicated value or ± 1 ° C, whichever greater) ± 1 digit max.
Analog input: ± 0.5% FS ± 1 digit max.
0.1 to 999.9 EU (in units of 0.1 EU)
0.1 to 999.9 EU (in units of 0.1 EU)
0 to 3999 s (in units of 1 s)
0 to 3999 s (in units of 1 s)
1 to 99 s (in units of 1 s)
0.0% to 100.0% (in units of 0.1%)
− 1999 to 9999 (decimal point position depends on input type)
500 ms
20 M Ω min. (at 500 VDC megger)
2000 VAC, 50 or 60 Hz for 1 min (between different charging terminals)
2
10 to 55 Hz, 10 m/s
for 2 hours each in X, Y and Z directions
2
300 m/s
, 3 times each in 3 axes, 6 directions (relay: 100 m/s
Approx. 90 g
Front panel: NEMA4X for indoor use (equivalent to IP66), rear case: IP20, terminals: IP00
EEPROM (non-volatile memory) (number of writes: 100,000)
ESD Immunity:
Radiated Electromagnetic Field Immunity: IEC 61000-4-3
Burst Immunity:
Surge Immunity:
Conducted Disturbance Immunity: IEC 61000-4-6:
Voltage Dip/Interrupting Immunity: IEC 61000-4-11
Radiated Emission:
Conducted Emission:
UL 61010C-1 (Listing)
CSA C22.2 No. 1010.1 (Evaluated by UL.)
EN 61010-1:
IEC 61010-1:
2
Mounting bracket: approx. 10 g
IEC 61000-4-2:
4 kV: Contact discharge
8 kV: Air discharge
10 V/m (80 MHz to 1 GHz amplitude modulated)
IEC 61000-4-4:
2 kV: Power lines
1 kV: I/O signal lines
IEC 61000-4-5:
1 kV: Normal mode (power lines and output lines)
2 kV: Common mode (power lines and output lines)
3 V: (0.16 to 80 MHz)
0.5 cycle, 100% (rated voltage)
EN 61326 Class A
EN 61326 Class A
2001
2001
Digital Temperature Controllers
)
E5GN
5