Automatic
Electronic Diagnostics
This water softener has a self-diagnostic
function for the electrical system (except input power
and/or
water meter). The water softener monitors electronic
components
and circuits for correct operation.
If a malfunction
occurs, an error code appears in the display.
The troubleshooting
chart shows the error codes that could appear, and the possible malfunctions
for
each code.
While an error code appears in the display, all buttons are inoperable except the PROGRAM
button.
PROGRAM
remains operational
so the service person can perform the Manual Advance Diagnostics,
see below, to further isolate the problem.
Manual Advance Diagnostics
Use the following procedures
to advance the water softener through the regeneration
cycles to check
operation.
Lift off the Salt Hole Cover, remove the top cover by unlocking
the tabs in the back and rocking
forward, to observe cam and switch operation during valve rotation.
1.
Press and hold (_
PROGRAM
for 3 seconds until 000 - - shows in the display.
i-it"11-1
s_,i_ U UU
2.
The first 3 digits indicate water meter operation as folk)ws:
000 (steady) =
Soft water not in use, and no flow through the meter.
Open a nearby soft water faucet.
000 to 140 (continual)
= Repeats display for each galkm of water passing through the meter.
NOTE:
If you don't get a reading in the display, with faucet open, pull the sensor from the
valve outlet port. Pass a small magnet back and forth in front of the sensor. You should
get a reading in the display. If you get a reading, unhook the in and out plumbing and
check the turbine for binding.
/
/-Zmoto
sensor
position switch _-_(
housing
J
iI
turbine
turbine
support & shaft
3.
.
valve outlet
Symbols in the display indicate POSITION
switch operation.
i-i1"11-1
i-i1"11-11
Switch is open
,,11i# UL,
L,
"11;#
U|JL'
I_ Switch is closed
(cam not rotating)
I-''"_._-
.._.__
(Cam rotating)
L
Use the O
RECHARGE
button to manually
advance the valve into each cycle and check correct
switch
operation.