Automatic Electronic Diagnostics; Manual Advance Diagnostics - Whirlpool WHES33 Installation And Operation Manual

Demand controlled water softener
Table of Contents

Advertisement

Troubleshooting

AUTOMATIC ELECTRONIC DIAGNOSTICS

This water softener has a self-diagnostic function for
the electrical system (except input power and/or water
meter). The water softener monitors electronic com-
ponents and circuits for correct operation. If a mal-
function occurs, an error code appears in the display.
While an error code appears in the display, all buttons
are inoperable except the PROGRAM button. PRO-
GRAM remains operational so the service person can
perform the Manual Advance Diagnostics, see below,
to further isolate the problem.
Procedure for removing error code from dis-
play:
1. Unplug transformer from electrical outlet.
2. Correct problem.
3. Plug in transformer.
4. Wait 8 minutes. The error code will return if
the problem was not corrected.

MANUAL ADVANCE DIAGNOSTICS

Use the following procedures to advance the water
softener through the regeneration cycles to check
operation.
Lift off the salt lid, remove the top cover by unlocking
the tabs in the back and rocking forward, to observe
cam and switch operation during valve rotation.
1. Press and hold PROGRAM for 3 seconds until
"000" shows in the display, then release.
2. The 3 digits indicate water meter operation as fol-
lows:
000 (steady) = Soft water not in use, and no flow
through the meter.
Open a nearby soft water faucet.
000 to 199 (continual) = Repeats for each gallon
(Models WHES30 & WHES33)
FIG. 48
of water passing through
the meter.
3. Symbols in the display indicate POSITION switch
operation (See Figure 49).
Switch is open
(Cam not rotating)
4. Use the RECHARGE button to manually advance
the valve into each cycle and check correct switch
operation.
NOTE: Be sure water is in contact with the salt, and
not separated by a salt bridge (See "Breaking
A Salt Bridge" section).
5. While in this diagnostic screen, the following infor-
mation is available and may be beneficial for vari-
ous reasons. This information is retained by the
computer from the first time electrical power is
applied to the electronic controller.
a. Press the
days this electronic control has had electrical
power applied.
s
b. Press the
ber of regenerations initiated by this electronic
control since the code number was entered.
6. Press and hold the PROGRAM button until the
model code ("LE31" for Model WHES30 or "LE33"
for Model WHES33) shows in the display. This
code identifies the softener model. If an incorrect
model code is displayed, the softener will operate
on incorrect configuration data.
7. To change the code number, press the
s
DOWN button until the correct code shows.
8. To return to the present time display, press the
PROGRAM button.
22
Switch is closed
(Cam rotating)
UP button to display the number of
DOWN button to display the num-
FIG. 49
FIG. 50
UP or

Advertisement

Table of Contents
loading

This manual is also suitable for:

Whes30Whes20

Table of Contents