Installing the air conditioner
Connecting the power terminal
Connect the cables to the terminal board with solderless ring terminals.
Only sue the certified and rated cables and make sure to firmly connect them without applying any external force to the
terminal.
Connect with a driver and a wrench that are able to apply the rated torque to the screws.
Connect the terminal screws according to the rated tightening torque. If the terminal is loose, fire can occur due to arc
heat generation and if the terminal is too tight, terminal board could get damaged.
Tightening torque for terminal (kgf∙cm)
Screw
When connecting two cables to one terminal, separate the solderless terminal up and
down to prevent it from getting loose. Place the thin cable upward and the thick cable
downward. Fix the power cable with a cable tie.
M3
M3.5
5.0 ~ 7.5
8.0 ~ 12.0
Solderless ring terminal
ENGLISH-44
M4
M5
12.0 ~ 18.0
20.0 ~ 30.0
Cable tie
Thin cable
Thick cable
M6
25.0 ~ 37.5