Installation

Installation

Mount on Wall

1. Ensure the wall is strong enough to support the
weight of the pump assembly and accessories, fluid,
hoses, and stress caused during pump operation.
2. Ensure that the mounting location has sufficient
clearance for easy operator access.
3. Position the wall bracket at a convenient height,
ensuring that there is sufficient clearance for the
fluid suction line and for servicing the lower.
4. Drill four 7/16 in. (11 mm) holes using the bracket as
a template. Use any of the three mounting hole
groupings in the bracket. See Mounting Hole Dia-
gram, page 18.
5. Bolt the bracket securely to the wall using bolts and
washers designed to hold in the wall's construction.
6. Attach the pump assembly to the mounting bracket.
7. Connect air and fluid hoses.

Grounding

The equipment must be grounded to reduce the risk
of static sparking. Static sparking can cause fumes to
ignite or explode. Grounding provides an escape wire
for the electric current.
Pump: use ground wire and clamp (supplied). See F
1. Use the ground screw (GS) and lock washer (LW) to
attach the ground wire (N) at the rear of the air motor.
Tighten the screw securely. Connect the other end of the
ground wire to a true earth ground.
8
GS, LW
F
. 1. Ground Wire
IG
Air and fluid hoses: use only electrically conductive
hoses.
Air compressor: follow manufacturer's recommenda-
tions.
Spray gun / Dispense valve: ground through connec-
tion to a properly grounded fluid hose and pump.
Fluid supply container: follow local code.
Object being sprayed: follow local code.
Solvent pails used when flushing: follow local code.
Use only conductive metal pails, placed on a grounded
surface. Do not place the pail on a nonconductive sur-
face, such as paper or cardboard, which interrupts
grounding continuity.
To maintain grounding continuity when flushing or
relieving pressure: hold metal part of the spray
gun/dispense valve firmly to the side of a grounded
metal pail, then trigger the gun/valve.

Flush Before Using Equipment

The equipment was tested with lightweight oil, which is
.
IG
left in the fluid passages to protect parts. To avoid con-
taminating your fluid with oil, flush the equipment with a
compatible solvent before using the equipment. See
your respective pump manual. See Related Manuals,
page 2.