Burner – for burning and feeding fuel.
Burning chamber is cube shaped – it is attached to the housing of boiler. It is used to put in a burner and to burn
fuel.
Fuel bunker (5.) – attached over the burning chamber and it is used to hold fuel.
Fan (2.) – for air supply. Flow of supplied air is adjusted by air flow regulator, which ensures optimal burning
conditions.
Temperature regulator (contact thermostat) – installed on piping fed by boiler. For controlling temperature of
outgoing water and for controlling the fan.
Airflow regulator (3.) – installed in burner. Secondary air supply in into burning zone is determined – for
optimization of burning conditions. Adjustment is carried out during first ignition by using analyzer of gas.
After positioning the carriage (4.) screw must be fully tightened, so that there would be minimal space between
carriage and burner.
Boiler is designed to be used with pellet burner, fired with 6 – 8 mm wood pellets. Pellets of varying quality can be used.
2.3 Pellet burner
2.4. Fuel